<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T06:49:44Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/41284" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/41284</identifier><datestamp>2022-01-13T07:54:37Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Brian LaBombard and Steven J. Wukitch.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Graves, Timothy P. (Timothy Paul)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-04-23T14:40:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-04-23T14:40:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/41284</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">213481240</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 159-166).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Multipactor discharges are a resonant condition in which electrons impact a surface in phase with an alternating electric field. The discharge is sustained by electron multiplication from secondary emission. As motivation, multipactor discharges can adversely affect many different rf systems in vacuum, and this work provides an improved general understanding of multipactor and gives promising results for improved performance and reliability of these systems. The Coaxial Multipactor Experiment (CMX) creates and investigates multipactor discharges in both parallel plate and coaxial geometries at very high frequency (VHF). CMX provides the first detailed investigation of multipactor energy distribution functions for both coaxial and parallel plate geometries with the use of retarding potential analyzers (RPA). A 1-D particle tracking simulation supports these experimental distributions and yields the underlying physics behind the distribution shape. Experimental and simulation energy distributions have a low energy population of defocused electrons due to space charge effects and RPA emission, and a high energy population responsible for sustaining the discharge. Results show a higher energy distribution for the coaxial geometry as compared to the parallel plate geometry with the same electrode spacing, implying that coaxial geometries are more susceptible to multipactor. These results are supported by CMX susceptibility data, which are provided for both coaxial and parallel plate electrodes. Lastly, similar multipactor experiments were performed on Alcator C-Mod rf systems, allowing the discovery of multipactor-induced glow discharge in these systems.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) Results suggest the onset of this glow discharge causes the observed C-Mod neutral pressure limits. These results are further supported by CMX experiments, and a new, 50 pim sandblasted copper surface treatment has been shown to sufficiently lower 6 &lt; 1 for multipactor prevention on CMX and raise the minimum pressure for glow discharge breakdown. This surface treatment shows no significant degradation of high voltage handling, and it is proposed for implementation on the multipactor-susceptible regions of C-Mod rf systems.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Timothy P. Graves.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">166 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by &#xd;
copyright. They may be viewed from this source for any purpose, but &#xd;
reproduction or distribution in any format is prohibited without written &#xd;
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Experimental investigation of electron multipactor discharges at very high frequency</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="bbce3c01-aa26-42d3-9d6e-f1699c56bf4b">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Experimental investigation of electron multipactor discharges at very high frequency&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Graves, Timothy P. (Timothy Paul)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Science and Engineering.&lt;/Keyword>
   	&lt;Abstract>Multipactor discharges are a resonant condition in which electrons impact a surface in phase with an alternating electric field. The discharge is sustained by electron multiplication from secondary emission. As motivation, multipactor discharges can adversely affect many different rf systems in vacuum, and this work provides an improved general understanding of multipactor and gives promising results for improved performance and reliability of these systems. The Coaxial Multipactor Experiment (CMX) creates and investigates multipactor discharges in both parallel plate and coaxial geometries at very high frequency (VHF). CMX provides the first detailed investigation of multipactor energy distribution functions for both coaxial and parallel plate geometries with the use of retarding potential analyzers (RPA). A 1-D particle tracking simulation supports these experimental distributions and yields the underlying physics behind the distribution shape. Experimental and simulation energy distributions have a low energy population of defocused electrons due to space charge effects and RPA emission, and a high energy population responsible for sustaining the discharge. Results show a higher energy distribution for the coaxial geometry as compared to the parallel plate geometry with the same electrode spacing, implying that coaxial geometries are more susceptible to multipactor. These results are supported by CMX susceptibility data, which are provided for both coaxial and parallel plate electrodes. Lastly, similar multipactor experiments were performed on Alcator C-Mod rf systems, allowing the discovery of multipactor-induced glow discharge in these systems.&lt;/Abstract>
   	&lt;Abstract>(cont.) Results suggest the onset of this glow discharge causes the observed C-Mod neutral pressure limits. These results are further supported by CMX experiments, and a new, 50 pim sandblasted copper surface treatment has been shown to sufficiently lower 6 &amp;lt; 1 for multipactor prevention on CMX and raise the minimum pressure for glow discharge breakdown. This surface treatment shows no significant degradation of high voltage handling, and it is proposed for implementation on the multipactor-susceptible regions of C-Mod rf systems.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>