<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T11:33:32Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/42297" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/42297</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Guoan Li and Derek Rowell.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Suggs, Jeremy F. (Jeremy Floyd), 1976-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-09-03T15:15:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-09-03T15:15:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/42297</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">232358861</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Sc. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 240-271).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">While contempary total knee arthroplasty has been successful in improving the quality of life for those suffering from severe osteoarthritis, the function of these patients has not reached normal levels for their age group. Thus, there is an increasing need to improve total knee arthroplasty techniques to allow patients to function normally. We currently have limited knowledge about how current knee arthroplasties behave in-vivo, but this information could be pivotal in designing new implants and surgical techniques. Therefore, the objective of this work was to develop the Dual Fluoroscopic Imaging System, a non-invasive imaging system capable of measuring in-vivo knee kinematics in all degrees of freedom. This system was used to investigate factors that may affect patient function after total knee arthroplasty. The feasibility of using kinematic data obtained using this system to analyze wear of the polyethylene insert was also explored The system was shown to be repeatable and accurate in determining the pose of the TKA components in all degrees of freedom. Six degree-of-freedom kinematics and articular contact motion were measured in-vivo. Data was obtained for patients with two typical classes of TKA, cruciate-retaining and cruciate-substituting, and the function of conventional implants was compared to that of more recent high flexion designs. In general, no differences were detected between these groups. Further, no factors such as age, weight, PCL management, or kinematics, were found to correlate with flexion capability. Future studies should investigate changes in knee structures from the preoperative state to the postoperative state. Preliminary estimates of polyethylene stresses suggested great potential in using the Dual Fluoroscopic Imaging System in developing a model of in-vivo polyethylene wear.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Jeremy F. Suggs.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Sc.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">271 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="d77ee49a-3041-4f35-bf66-d00f5b463486">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Suggs, Jeremy F. (Jeremy Floyd), 1976-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>While contempary total knee arthroplasty has been successful in improving the quality of life for those suffering from severe osteoarthritis, the function of these patients has not reached normal levels for their age group. Thus, there is an increasing need to improve total knee arthroplasty techniques to allow patients to function normally. We currently have limited knowledge about how current knee arthroplasties behave in-vivo, but this information could be pivotal in designing new implants and surgical techniques. Therefore, the objective of this work was to develop the Dual Fluoroscopic Imaging System, a non-invasive imaging system capable of measuring in-vivo knee kinematics in all degrees of freedom. This system was used to investigate factors that may affect patient function after total knee arthroplasty. The feasibility of using kinematic data obtained using this system to analyze wear of the polyethylene insert was also explored The system was shown to be repeatable and accurate in determining the pose of the TKA components in all degrees of freedom. Six degree-of-freedom kinematics and articular contact motion were measured in-vivo. Data was obtained for patients with two typical classes of TKA, cruciate-retaining and cruciate-substituting, and the function of conventional implants was compared to that of more recent high flexion designs. In general, no differences were detected between these groups. Further, no factors such as age, weight, PCL management, or kinematics, were found to correlate with flexion capability. Future studies should investigate changes in knee structures from the preoperative state to the postoperative state. Preliminary estimates of polyethylene stresses suggested great potential in using the Dual Fluoroscopic Imaging System in developing a model of in-vivo polyethylene wear.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>