<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-21T22:31:06Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/43017" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/43017</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Todd Thorsen.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Rodriguez, Rosa H</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-11-07T18:52:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-11-07T18:52:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/43017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">240704461</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 63-64).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Rosa H. Rodriguez.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">64 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design, fabrication, and testing of a multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8215a455-3aac-4a22-950a-6eadd773a6c1">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design, fabrication, and testing of a multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro&lt;/Title>
   	&lt;Subtitle>Multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Rodriguez, Rosa H&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>