<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T11:13:30Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/44837" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/44837</identifier><datestamp>2022-01-13T07:54:37Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Richard C. Lanza.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Lee, Tiffany (Tiffany Ting)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-03-16T19:49:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-03-16T19:49:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/44837</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">301577354</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 50).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Tiffany Lee.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">50 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="3e585f66-69cd-4556-b7fd-306714379edb">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lee, Tiffany (Tiffany Ting)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Science and Engineering.&lt;/Keyword>
   	&lt;Abstract>Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>