<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T23:13:28Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/45748" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/45748</identifier><datestamp>2022-01-13T07:54:29Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">James G. Fujimoto.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Srinivasan, Vivek Jay</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-06-30T16:11:08Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-06-30T16:11:08Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/45748</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">298116698</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called "Fourier domain" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Vivek Jay Srinivasan.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">234 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">High-speed Fourier domain OCT for structural and functional imaging of the retina</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="475b6ade-dcb0-4cbb-8227-08d3adc42804">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina&lt;/Title>
   	&lt;Subtitle>High-speed Fourier domain OCT for structural and functional imaging of the retina&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Srinivasan, Vivek Jay&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called &amp;quot;Fourier domain&amp;quot; because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>