<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T22:34:25Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/46060" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/46060</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">McEuen, Scott Jacob</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-06-30T17:12:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-06-30T17:12:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/46060</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">374561627</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 61-62).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This thesis describes the design and characterization of a microcalorimeter used to aid drug discovery. There are four key functional requirements for the device: (1.) 8.4 [mu]J energy resolution, (2.) 20 [mu]L reactant volume (combined total), (3.) 10% experimental variance, and (4.) 100 [mu]K baseline calorimeter drift over a two hour period. The calorimeter utilizes a novel heat sensor. This heat sensor combines thermal expansion and the dynamic response of an oscillating ribbon to transduce the signal from a heat event. A vacuum chamber improved the sensitivity of the sensor by approximately an order of magnitude by significantly reducing the losses due to air friction in the resonant sensor. Additional components such as a position sensor, temperature controlled vacuum chamber, software, and a syringe pump were constructed to complete the calorimeter system. The current calorimeter prototype nearly meets each functional requirement. In addition, the current sensitivity of the instrument is near that of a commercially available calorimeter but uses almost two orders of magnitude less solution. Finally, all of our calorimeter components are designed, built, integrated, and ready to begin more rigorous biological solution experimentation.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Scott Jacob McEuen.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">62 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The design and characterization of a microcalorimeter to aid drug discovery</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="7e7336b2-8656-4a59-8642-ae7bf94d7517">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>The design and characterization of a microcalorimeter to aid drug discovery&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>McEuen, Scott Jacob&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>This thesis describes the design and characterization of a microcalorimeter used to aid drug discovery. There are four key functional requirements for the device: (1.) 8.4 [mu]J energy resolution, (2.) 20 [mu]L reactant volume (combined total), (3.) 10% experimental variance, and (4.) 100 [mu]K baseline calorimeter drift over a two hour period. The calorimeter utilizes a novel heat sensor. This heat sensor combines thermal expansion and the dynamic response of an oscillating ribbon to transduce the signal from a heat event. A vacuum chamber improved the sensitivity of the sensor by approximately an order of magnitude by significantly reducing the losses due to air friction in the resonant sensor. Additional components such as a position sensor, temperature controlled vacuum chamber, software, and a syringe pump were constructed to complete the calorimeter system. The current calorimeter prototype nearly meets each functional requirement. In addition, the current sensitivity of the instrument is near that of a commercially available calorimeter but uses almost two orders of magnitude less solution. Finally, all of our calorimeter components are designed, built, integrated, and ready to begin more rigorous biological solution experimentation.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>