<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T19:21:53Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/46384" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/46384</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Guoan Li and Derek Rowell.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Massimini, Daniel Frank</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-08-25T18:01:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-08-25T18:01:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/46384</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">426493527</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This electronic version was submitted by the student author.  The certified thesis is available in the Institute Archives and Special Collections.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">MIT Institute Archives copy: with CD-ROM; divisional library copy with no CD-ROM.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 99-104).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Knowledge of in-vivo glenohumeral joint biomechanics after total shoulder arthroplasty are important for the improvement of patient function, implant longevity and surgical technique. No data has been published on the in-vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. Therefore, the objectives of this thesis were to determine the in-vivo glenohumeral joint contact locations and humeral head translations in patients after total shoulder arthroplasty. First, a non-invasive three dimensional fluoroscopic image matching method was developed and validated for use in the shoulder joint complex. Next, a group of patients that have undergone clinically successful total shoulder arthroplasty surgeries were recruited for study and imaged by the fluoroscopic imaging technique.The fluoroscopic imaging system was recreated in a virtual environment and the in vivo kinematics that were recorded by the fluoroscopes were recreated with three dimensional models. The contact centroids of the glenohumeral joint and humeral head translations were measured using solid modeling software. In summary, this thesis quantified the in-vivo glenohumeral joint contact locations and humeral head translations after total shoulder arthroplasty. These data provides surgeons and engineers valuable information for developing surgical treatments that may better help recreate 'normal' motion of the shoulder after total shoulder arthroplasty.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Daniel Frank Massimini.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">104 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="requires" lang="en_US">System requirements: CD-ROM drive.</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Technique and application of a non-invasive three dimensional image matching method for the study of total shoulder arthroplasty</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="a238712b-855f-4da4-a958-9d3998d049cd">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Technique and application of a non-invasive three dimensional image matching method for the study of total shoulder arthroplasty&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Massimini, Daniel Frank&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword&gt;Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Knowledge of in-vivo glenohumeral joint biomechanics after total shoulder arthroplasty are important for the improvement of patient function, implant longevity and surgical technique. No data has been published on the in-vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. Therefore, the objectives of this thesis were to determine the in-vivo glenohumeral joint contact locations and humeral head translations in patients after total shoulder arthroplasty. First, a non-invasive three dimensional fluoroscopic image matching method was developed and validated for use in the shoulder joint complex. Next, a group of patients that have undergone clinically successful total shoulder arthroplasty surgeries were recruited for study and imaged by the fluoroscopic imaging technique.The fluoroscopic imaging system was recreated in a virtual environment and the in vivo kinematics that were recorded by the fluoroscopes were recreated with three dimensional models. The contact centroids of the glenohumeral joint and humeral head translations were measured using solid modeling software. In summary, this thesis quantified the in-vivo glenohumeral joint contact locations and humeral head translations after total shoulder arthroplasty. These data provides surgeons and engineers valuable information for developing surgical treatments that may better help recreate &amp;apos;normal&amp;apos; motion of the shoulder after total shoulder arthroplasty.&lt;/Abstract&gt;
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>