<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T10:45:41Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/50547" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/50547</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Jose G. Venegas.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Whitbourne, Peta Gaye</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-01-07T20:51:36Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-01-07T20:51:36Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">1998</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">1998</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/50547</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">44075592</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1998.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 63-66).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">One to three percent of the Open Heart Surgery procedures have abnormal bleeding due to acquired platelet dysfunction. Standard clotting tests to determine the cause of bleeding usually take between 25 and 60 minutes to get results. This time frame is not useful for deciding what type of treatment to give to a patient. More importantly, the standard clotting tests is they cannot determine platelet function. The Thrombo-Visco Elastogram (TVE) is a new test that provides results in less than 15 minutes and has the potential to evaluate platelet function. In this study, we used the TVE test to assess viscoelasticity of clotting blood from patients before and after CPB. For each patient and condition, we tested the blood alone and after incubation with a saturation concentration of ReoProTM, a glycoprotein Ilb/Illa inhibitor. The major findings of this study are: 1) The TVE device is capable of determining with accuracy quantitative changes in blood viscoelasticity during clotting; 2) The TVE-derived coagulation parameters maximum elastic modulus (Emax), maximum rate of change of elastic modulus (E'max), maximum viscosity ([eta]max), and maximum rate of change of viscosity ([eta]'max) and the coagulation parameters prothrombin time (PT), platelet count, fibrinogen concentration and hematocrit are all affected by CPB; 3) The TVE-derived parameters were all substantially affected by incubation of the blood with the platelet GP inhibitor suggesting that these parameters are exquisitely sensitive to platelet function; and 4) In ReoProTM-free blood samples, values of E'max for all patients, before and after CPB, could be predicted as a function of platelet count, fibrinogen concentration and hematocrit. We concluded that the TVE/ReoProTM assay has the potential to assess the contribution of platelet function and soluble components to coagulation in a quantitative, reproducible and practical manner.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Peta Gaye Sonya Whitbourne.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">66 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by &#xd;
copyright. They may be viewed from this source for any purpose, but &#xd;
reproduction or distribution in any format is prohibited without written &#xd;
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Changes in the clotting viscoelasticity caused by cardiopulmonary bypass (CPB) surgery</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="aa9e34a8-e338-4d85-9273-3b0568a87e77">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Changes in the clotting viscoelasticity caused by cardiopulmonary bypass (CPB) surgery&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>1998&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Whitbourne, Peta Gaye&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>One to three percent of the Open Heart Surgery procedures have abnormal bleeding due to acquired platelet dysfunction. Standard clotting tests to determine the cause of bleeding usually take between 25 and 60 minutes to get results. This time frame is not useful for deciding what type of treatment to give to a patient. More importantly, the standard clotting tests is they cannot determine platelet function. The Thrombo-Visco Elastogram (TVE) is a new test that provides results in less than 15 minutes and has the potential to evaluate platelet function. In this study, we used the TVE test to assess viscoelasticity of clotting blood from patients before and after CPB. For each patient and condition, we tested the blood alone and after incubation with a saturation concentration of ReoProTM, a glycoprotein Ilb/Illa inhibitor. The major findings of this study are: 1) The TVE device is capable of determining with accuracy quantitative changes in blood viscoelasticity during clotting; 2) The TVE-derived coagulation parameters maximum elastic modulus (Emax), maximum rate of change of elastic modulus (E&amp;apos;max), maximum viscosity ([eta]max), and maximum rate of change of viscosity ([eta]&amp;apos;max) and the coagulation parameters prothrombin time (PT), platelet count, fibrinogen concentration and hematocrit are all affected by CPB; 3) The TVE-derived parameters were all substantially affected by incubation of the blood with the platelet GP inhibitor suggesting that these parameters are exquisitely sensitive to platelet function; and 4) In ReoProTM-free blood samples, values of E&amp;apos;max for all patients, before and after CPB, could be predicted as a function of platelet count, fibrinogen concentration and hematocrit. We concluded that the TVE/ReoProTM assay has the potential to assess the contribution of platelet function and soluble components to coagulation in a quantitative, reproducible and practical manner.&lt;/Abstract>