<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T22:58:35Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/53279" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/53279</identifier><datestamp>2022-01-13T07:54:37Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Richard C. Lanza and Jacquelyn C. Yanch.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Bell, Jayna T. (Jayna Teresa)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-03-25T15:25:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-03-25T15:25:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/53279</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">547364486</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2009.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 117-118).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Standoff detection of improvised explosive devices (IEDs) is a continuing problem for the U.S. military. Current X-ray detection systems cannot detect explosives at distances above a few meters and with a source-detector system moving in relation to the target. The aim of this study is to determine the feasibility of a large-area, Coded-Aperture Imaging (CAI) system using X-Ray backscatter as the source of radiation. A moving source-detector system required development of a new reconstruction technique, dynamic reconstruction (DR), which continually back-projects detected events on an event-by-event basis. This research imaged multiple low-Z (polyethylene and water-filled), area targets with backscattered X-rays using standard medical imaging equipment, coded aperture masks with ideal bi-level autocorrelation properties, and dynamic reconstruction (DR). Lower fill factor apertures were the primary metric investigated because contrast was shown to be inversely related to the mask's percentage of open area. This study experimentally determined the optimal mask fill factor, gamma camera imaging protocols, and experimental geometry by examining the resulting effects on image quality. Reconstructed images were analyzed for Contrast-to-noise ratio (CNR), Signal-to-noise Ratio (SNR), resolution, sharpness, the uniformity of the background (artifacts). In addition to changing the fill factor, additional methods of improving the contrast included changing the experimental geometry, reducing the X-ray tube filtration, and widening the X-ray source's cone beam (FOV).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) 14 studies were performed that found 25% fill factor mask reconstructions had the highest average CNR (14.7), compared to 50% and 12.5% fill factor (CNRs 8.50 and 6.9, respectively) with a system resolution of 25 mm at the target. Thus, this study's techniques confirmed that large-area, low fill factor coded apertures could successfully be used, in conjunction with dynamic reconstruction, to image complex, extended scenes at 5 meters with capabilities of up to 50 meters or more.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Jayna T. Bell.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">118 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Detection of improvised explosive devices at long-range using coded aperture imaging of backscattered X-rays with dynamic reconstruction</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Detection of IEDs at long-range using CAI of backscattered X-rays with DR</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="188aa9d2-16ec-4211-8bf3-efb879b18f08">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Detection of improvised explosive devices at long-range using coded aperture imaging of backscattered X-rays with dynamic reconstruction&lt;/Title>
   	&lt;Subtitle>Detection of IEDs at long-range using CAI of backscattered X-rays with DR&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Bell, Jayna T. (Jayna Teresa)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Science and Engineering.&lt;/Keyword>
   	&lt;Abstract>Standoff detection of improvised explosive devices (IEDs) is a continuing problem for the U.S. military. Current X-ray detection systems cannot detect explosives at distances above a few meters and with a source-detector system moving in relation to the target. The aim of this study is to determine the feasibility of a large-area, Coded-Aperture Imaging (CAI) system using X-Ray backscatter as the source of radiation. A moving source-detector system required development of a new reconstruction technique, dynamic reconstruction (DR), which continually back-projects detected events on an event-by-event basis. This research imaged multiple low-Z (polyethylene and water-filled), area targets with backscattered X-rays using standard medical imaging equipment, coded aperture masks with ideal bi-level autocorrelation properties, and dynamic reconstruction (DR). Lower fill factor apertures were the primary metric investigated because contrast was shown to be inversely related to the mask&amp;apos;s percentage of open area. This study experimentally determined the optimal mask fill factor, gamma camera imaging protocols, and experimental geometry by examining the resulting effects on image quality. Reconstructed images were analyzed for Contrast-to-noise ratio (CNR), Signal-to-noise Ratio (SNR), resolution, sharpness, the uniformity of the background (artifacts). In addition to changing the fill factor, additional methods of improving the contrast included changing the experimental geometry, reducing the X-ray tube filtration, and widening the X-ray source&amp;apos;s cone beam (FOV).&lt;/Abstract>
   	&lt;Abstract>(cont.) 14 studies were performed that found 25% fill factor mask reconstructions had the highest average CNR (14.7), compared to 50% and 12.5% fill factor (CNRs 8.50 and 6.9, respectively) with a system resolution of 25 mm at the target. Thus, this study&amp;apos;s techniques confirmed that large-area, low fill factor coded apertures could successfully be used, in conjunction with dynamic reconstruction, to image complex, extended scenes at 5 meters with capabilities of up to 50 meters or more.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>