<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T21:31:35Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/55231" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/55231</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Duane S. Boning.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Liu, Haoyu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-05-25T21:07:33Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-05-25T21:07:33Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2009</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/55231</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">611962803</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 70-71).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Reducing energy consumption without compromising the quality of products and the comfort of occupants is important in maintaining the competence of a pharmaceutical company. An energy management tool is developed to monitor the energy efficiency and calculate the cooling load. After analyzing the Energy Utilization Index (EUI) and cooling load, the Heating, Ventilation and Air-Conditioning (HVAC) system is identified as the major energy consumer in the plant. The AHU operation schedule in the office building is modified to reduce waste while accommodating the working schedule of employees. Motion detection lighting control is implemented in office areas to reduce waste from unnecessary lighting. Revision of the AHU operating schedule in manufacturing building can reduce electricity use by 16.5% while the implementation of other recommendations can save more than $50,000 in a six month period. A spreadsheet is developed to optimize the dehumidifier setting and the set point temperature of chilled water and off coil air.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Haoyu Liu.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">79 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Improving energy efficiency in a pharmaceutical manufacturing environment : analysis of EUI and cooling load</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="06207402-0d59-45fc-a936-26af822a56b8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Improving energy efficiency in a pharmaceutical manufacturing environment : analysis of EUI and cooling load&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009&lt;/PublicationDate&gt;
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liu, Haoyu&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword&gt;
   	&lt;Abstract>Reducing energy consumption without compromising the quality of products and the comfort of occupants is important in maintaining the competence of a pharmaceutical company. An energy management tool is developed to monitor the energy efficiency and calculate the cooling load. After analyzing the Energy Utilization Index (EUI) and cooling load, the Heating, Ventilation and Air-Conditioning (HVAC) system is identified as the major energy consumer in the plant. The AHU operation schedule in the office building is modified to reduce waste while accommodating the working schedule of employees. Motion detection lighting control is implemented in office areas to reduce waste from unnecessary lighting. Revision of the AHU operating schedule in manufacturing building can reduce electricity use by 16.5% while the implementation of other recommendations can save more than $50,000 in a six month period. A spreadsheet is developed to optimize the dehumidifier setting and the set point temperature of chilled water and off coil air.&lt;/Abstract>