<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T05:52:41Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/55267" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/55267</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Martin L. Yarmush.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Izamis, Maria-Louisa, 1979-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-05-25T21:12:35Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-05-25T21:12:35Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/55267</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">613208381</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 47-49).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Liver perfusion systems can be used as organ culture platforms for metabolic, genetic and systems engineering, tissue regeneration, pharmacokinetics, organ storage and marginal donor reconditioning for transplantation. The primary requirement of such a system is that it maintain ex vivo organ function in a stable manner for indefinite periods of time. The more physiologically relevant the perfusion system is, the lower the likelihood of incurring functional instability, and the greater the clinical relevance of the data obtained. Currently, a major limiting factor in achieving such a design is the absence of organ-specific in vivo data to standardize, evaluate and optimize the state of perfused livers. Oxygen uptake rate, the primary indicator of organ metabolism and therefore a likely important marker of organ viability, was chosen as one such parameter to be investigated. A systematic review and reproduction of numerous oxygenation conditions cited in the literature in addition to in vivo data sampling across the rat liver shows a significant paucity of oxygen uptake in perfusion compared to in vivo. The reasons stem largely from the biological and mechanical flow properties of the perfusate, but also from the altered metabolic state of the organ in perfusion. In the absence of an oxygen carrier, the liver became oxygen starved and lost functionality. The addition of erythrocytes significantly improved oxygen delivery rates while reducing the flow rate and damaging shear stress.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) However, as hematocrit approached physiological values perfusate viscosity became detrimentally high, causing severe structural and ultimately functional damage. Large strains of erythrocytes similarly impacted the liver. The addition of sodium heparin reduced erythrocyte-erythrocyte and erythrocyte-parenchyma interaction, thereby reducing sheer stress on the liver. The optimal oxygen carriers were small heparinized erythrocytes, such as goat or rat erythrocytes, at a hematocrit of 12%-20%. These conditions continued to provide adequate in vivo oxygen delivery rates and sustained organ structure and function.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Maria-Louisa Izamis.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">49 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Meeting the oxygen requirements of an isolated perfused rat liver</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="9ee92339-5015-4c6e-ab0a-5c1d000d1458">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Meeting the oxygen requirements of an isolated perfused rat liver&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Izamis, Maria-Louisa, 1979-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Liver perfusion systems can be used as organ culture platforms for metabolic, genetic and systems engineering, tissue regeneration, pharmacokinetics, organ storage and marginal donor reconditioning for transplantation. The primary requirement of such a system is that it maintain ex vivo organ function in a stable manner for indefinite periods of time. The more physiologically relevant the perfusion system is, the lower the likelihood of incurring functional instability, and the greater the clinical relevance of the data obtained. Currently, a major limiting factor in achieving such a design is the absence of organ-specific in vivo data to standardize, evaluate and optimize the state of perfused livers. Oxygen uptake rate, the primary indicator of organ metabolism and therefore a likely important marker of organ viability, was chosen as one such parameter to be investigated. A systematic review and reproduction of numerous oxygenation conditions cited in the literature in addition to in vivo data sampling across the rat liver shows a significant paucity of oxygen uptake in perfusion compared to in vivo. The reasons stem largely from the biological and mechanical flow properties of the perfusate, but also from the altered metabolic state of the organ in perfusion. In the absence of an oxygen carrier, the liver became oxygen starved and lost functionality. The addition of erythrocytes significantly improved oxygen delivery rates while reducing the flow rate and damaging shear stress.&lt;/Abstract>
   	&lt;Abstract>(cont.) However, as hematocrit approached physiological values perfusate viscosity became detrimentally high, causing severe structural and ultimately functional damage. Large strains of erythrocytes similarly impacted the liver. The addition of sodium heparin reduced erythrocyte-erythrocyte and erythrocyte-parenchyma interaction, thereby reducing sheer stress on the liver. The optimal oxygen carriers were small heparinized erythrocytes, such as goat or rat erythrocytes, at a hematocrit of 12%-20%. These conditions continued to provide adequate in vivo oxygen delivery rates and sustained organ structure and function.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>