<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T02:20:01Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/57705" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/57705</identifier><datestamp>2022-01-13T07:53:45Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Michael J. Cima.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Ling, Yibo</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Harvard University--MIT Division of Health Sciences and Technology</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-08-30T14:47:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-08-30T14:47:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/57705</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">655896883</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Page 104 blank. Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The monitoring of physiological biomarkers is fundamental to the diagnosis and treatment of disease. We describe here the development of molecular sensors which can be read by magnetic resonance (MR) relaxometry. MR is an advantageous bio-sensor readout because it can be determined from opaque samples and through intervening layers of matter. Wash steps can therefore be avoided in in vitro MR assays and non-invasive interrogation achieved for in vivo MR sensing. Functionalized magnetic nanoparticles originally developed as in vivo contrast agents have recently been adapted for use in magnetic relaxometry assays. The first half of this thesis describes a simple particle functionalization strategy and its application to the detection of myocardial infarction ("heart attack") associated biomarkers. The particles were subcutaneously implanted in the form of small discrete sensors and shown to be efficacious in measuring the physiological release of three protein biomarkers. Alternative contrast mechanisms may also be employed by MR readable sensors. The second half of this thesis introduces the novel use of 'smart' polymers which produce analyte-responsive changes in MR relaxivity. We show that MR responsive calcium-crosslinked and pH-swelling hydrogels can be incorporated within discrete sensors.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Yibo Ling.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">104 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Nuclear magnetic resonance readable sensors</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">NMR readable sensors</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="41ea0333-52d4-4c6c-8be7-621175fe051b">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Nuclear magnetic resonance readable sensors&lt;/Title>
   	&lt;Subtitle>NMR readable sensors&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Ling, Yibo&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Harvard University--MIT Division of Health Sciences and Technology.&lt;/Keyword>
   	&lt;Abstract>The monitoring of physiological biomarkers is fundamental to the diagnosis and treatment of disease. We describe here the development of molecular sensors which can be read by magnetic resonance (MR) relaxometry. MR is an advantageous bio-sensor readout because it can be determined from opaque samples and through intervening layers of matter. Wash steps can therefore be avoided in in vitro MR assays and non-invasive interrogation achieved for in vivo MR sensing. Functionalized magnetic nanoparticles originally developed as in vivo contrast agents have recently been adapted for use in magnetic relaxometry assays. The first half of this thesis describes a simple particle functionalization strategy and its application to the detection of myocardial infarction (&amp;quot;heart attack&amp;quot;) associated biomarkers. The particles were subcutaneously implanted in the form of small discrete sensors and shown to be efficacious in measuring the physiological release of three protein biomarkers. Alternative contrast mechanisms may also be employed by MR readable sensors. The second half of this thesis introduces the novel use of &amp;apos;smart&amp;apos; polymers which produce analyte-responsive changes in MR relaxivity. We show that MR responsive calcium-crosslinked and pH-swelling hydrogels can be incorporated within discrete sensors.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>