<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-21T02:21:30Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/58298" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/58298</identifier><datestamp>2022-01-13T07:53:45Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Martin L. Yarmush.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Izamis, Maria-Louisa, 1979-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Harvard University--MIT Division of Health Sciences and Technology</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-09-02T17:26:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-09-02T17:26:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/58298</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">655896860</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">There is a constant demand for enormous numbers of high quality hepatocytes in the fields of cell transplantation, pharmacotoxicology, tissue engineering, and bioartificial assist devices. The scarcity of viable hepatocytes necessitates the use of suboptimal sources including damaged donor organs that are not transplantable. Many of these organs have potentially reversible pathologies however, that could be treated via ex vivo perfusion thereby increasing their cell yield. With the intent to translate organ recovery by perfusion into the clinic, we engineered a very simple room temperature-operated ex vivo organ perfusion system to test a rat liver model of uncontrolled non-heart beating donors. Seventeen times as many hepatocytes were recovered from livers exposed to an hour of warm ischemia (WI, 34*C) compared to untreated WI livers in only 3 hours of perfusion. Further, fresh liver hepatocyte yields were also increased by 32% postperfusion, demonstrating that both damaged and healthy donor livers could benefit from this methodology. A linear correlation between cell yield and tissue ATP content was established. This enables an accurate prediction of cell recovery during preservation and can be used as a direct measure of organ viability and the trajectory of organ recovery during perfusion resuscitation. Further, a strong correlation between perfusion flow rate and cell yield was also established supporting the use of flow rates as low as possible without causing hypoperfusion or oxygen deprivation. Morphologically and functionally, perfusion-isolated hepatocytes generally performed comparably or better than fresh hepatocytes in cell suspension and plate culture. Cumulatively, these findings strongly support the ubiquitous use of organ perfusion systems in the clinic for optimal enhancement of donor grafts.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Maria-Louisa Izamis.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">242 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Ex vivo perfusion optimization of donor liver grafts for transplantation and cell isolation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="08b8d1f1-b7f9-48f4-ac10-014c338787da">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Ex vivo perfusion optimization of donor liver grafts for transplantation and cell isolation&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Izamis, Maria-Louisa, 1979-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Harvard University--MIT Division of Health Sciences and Technology.&lt;/Keyword>
   	&lt;Abstract>There is a constant demand for enormous numbers of high quality hepatocytes in the fields of cell transplantation, pharmacotoxicology, tissue engineering, and bioartificial assist devices. The scarcity of viable hepatocytes necessitates the use of suboptimal sources including damaged donor organs that are not transplantable. Many of these organs have potentially reversible pathologies however, that could be treated via ex vivo perfusion thereby increasing their cell yield. With the intent to translate organ recovery by perfusion into the clinic, we engineered a very simple room temperature-operated ex vivo organ perfusion system to test a rat liver model of uncontrolled non-heart beating donors. Seventeen times as many hepatocytes were recovered from livers exposed to an hour of warm ischemia (WI, 34*C) compared to untreated WI livers in only 3 hours of perfusion. Further, fresh liver hepatocyte yields were also increased by 32% postperfusion, demonstrating that both damaged and healthy donor livers could benefit from this methodology. A linear correlation between cell yield and tissue ATP content was established. This enables an accurate prediction of cell recovery during preservation and can be used as a direct measure of organ viability and the trajectory of organ recovery during perfusion resuscitation. Further, a strong correlation between perfusion flow rate and cell yield was also established supporting the use of flow rates as low as possible without causing hypoperfusion or oxygen deprivation. Morphologically and functionally, perfusion-isolated hepatocytes generally performed comparably or better than fresh hepatocytes in cell suspension and plate culture. Cumulatively, these findings strongly support the ubiquitous use of organ perfusion systems in the clinic for optimal enhancement of donor grafts.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>