<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T10:41:16Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/59900" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/59900</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Alexander H. Slocum.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Chen, Xuefeng, S.B. Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-11-08T17:43:09Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-11-08T17:43:09Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/59900</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">676694191</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 50).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">As MRI guided interventions are becoming more widely practiced, the goal of this thesis was to design an instrument guidance device for MRI-guided percutaneous interventions in closed bore systems, namely cryoablation procedures where multiple probes need to be placed to treat a tumor. Multiple meetings with researchers and clinicians the Brigham and Women's Hospital were conducted to understand the challenges currently faced by interventionists, to set functional requirements for the design of a system to overcome them, and to help select a clinically viable strategy. The strategy selected involved making a device that had two degrees of angular freedom about a remote center of motion located at the probe entry point on the skin. This device is designed to be incorporated with a custom built MR coil. Structural and finite element analysis was conducted for a number of different mechanism concepts to examine their stiffness and the effect of structural displacements on the end-point probe placement accuracy. The selected concept was a curved arm piece that travels around the pivot point on a circular base, and an additional needle holder that travels along the curved arm. The sliding parts were designed with five points of constraint so that only sliding motion was possible. Thumb screws were used for preload and locking so that the probe guide could be locked along a specific trajectory. The device was prototyped via stereolithography as a proof of concept. It was found that sanding was required to fit the parts together because of overbuild in the stereolithography process. The parts functioned as designed and demonstrated that a probe could be angled about a remote pivot point. However, wear of the plastic parts eventually caused increased play between the plastic parts. Further testing and optimization of the device is planned.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Xuefeng Chen.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">50 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Instrument guide for MRI-guided percutaneous interventions</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Instrument guide for Magnetic Resonance Imaging-guided percutaneous interventions</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2a48bca2-8d23-47e7-901b-c8f1a4b3aad7">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Instrument guide for MRI-guided percutaneous interventions&lt;/Title>
   	&lt;Subtitle>Instrument guide for Magnetic Resonance Imaging-guided percutaneous interventions&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Xuefeng, S.B. Massachusetts Institute of Technology&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>As MRI guided interventions are becoming more widely practiced, the goal of this thesis was to design an instrument guidance device for MRI-guided percutaneous interventions in closed bore systems, namely cryoablation procedures where multiple probes need to be placed to treat a tumor. Multiple meetings with researchers and clinicians the Brigham and Women&amp;apos;s Hospital were conducted to understand the challenges currently faced by interventionists, to set functional requirements for the design of a system to overcome them, and to help select a clinically viable strategy. The strategy selected involved making a device that had two degrees of angular freedom about a remote center of motion located at the probe entry point on the skin. This device is designed to be incorporated with a custom built MR coil. Structural and finite element analysis was conducted for a number of different mechanism concepts to examine their stiffness and the effect of structural displacements on the end-point probe placement accuracy. The selected concept was a curved arm piece that travels around the pivot point on a circular base, and an additional needle holder that travels along the curved arm. The sliding parts were designed with five points of constraint so that only sliding motion was possible. Thumb screws were used for preload and locking so that the probe guide could be locked along a specific trajectory. The device was prototyped via stereolithography as a proof of concept. It was found that sanding was required to fit the parts together because of overbuild in the stereolithography process. The parts functioned as designed and demonstrated that a probe could be angled about a remote pivot point. However, wear of the plastic parts eventually caused increased play between the plastic parts. Further testing and optimization of the device is planned.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>