<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T19:33:55Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/61611" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/61611</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Leon Glicksman.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Samouhos, Stephen V. (Stephen Vincent), 1982-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-03-07T15:23:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-03-07T15:23:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/61611</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">704682506</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 201-206).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The building sector of the United States currently consumes over 40% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted due to pathologically malfunctioning lighting and comfort conditioning systems. This thesis is focused on developing analytical methods embodied within useful software tools to quickly identify and evaluate those building system faults that cause large building energy inefficiencies. The technical contributions of this work include expert rules that adapt to HVAC equipment scale and operation, a general framework for applying probabilistic inference to HVAC fault detection and evaluation, and methods for sorting fault signals according to userdefined interests such as annual cost of energy inefficiencies. These contributions are particularly unique in their treatment of model and measurement uncertainty within the fault inference, and the careful consideration of user interests in fault evaluation. As a first step to developing this general framework for fault detection, I targeted first order faults such as simultaneous heating and cooling and imbalanced air flows within several large air-handling units in three buildings on the MIT campus. Experiments included the purposeful implementation of mechanical and software control programming faults on otherwise fault-free equipment. Between the five pieces of equipment, the software system successfully identified all previously known and experimentally implemented faults, as well as additional faults that had not been previously identified or imposed during the experiment. User testing and experiments show that embracing uncertainty within HVAC fault detection and evaluation is not only paramount to judicious fault inference but it is also central to gaining the trust and buy-in of system users who ultimately can apply fault detection information to actually fix and improve building operations.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Stephen Samouhos.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">207 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Building condition monitoring</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c3fc674c-dd9a-44b1-bebe-caea5af0746c">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Building condition monitoring&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Samouhos, Stephen V. (Stephen Vincent), 1982-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The building sector of the United States currently consumes over 40% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building&amp;apos;s annual energy consumption is unknowingly wasted due to pathologically malfunctioning lighting and comfort conditioning systems. This thesis is focused on developing analytical methods embodied within useful software tools to quickly identify and evaluate those building system faults that cause large building energy inefficiencies. The technical contributions of this work include expert rules that adapt to HVAC equipment scale and operation, a general framework for applying probabilistic inference to HVAC fault detection and evaluation, and methods for sorting fault signals according to userdefined interests such as annual cost of energy inefficiencies. These contributions are particularly unique in their treatment of model and measurement uncertainty within the fault inference, and the careful consideration of user interests in fault evaluation. As a first step to developing this general framework for fault detection, I targeted first order faults such as simultaneous heating and cooling and imbalanced air flows within several large air-handling units in three buildings on the MIT campus. Experiments included the purposeful implementation of mechanical and software control programming faults on otherwise fault-free equipment. Between the five pieces of equipment, the software system successfully identified all previously known and experimentally implemented faults, as well as additional faults that had not been previously identified or imposed during the experiment. User testing and experiments show that embracing uncertainty within HVAC fault detection and evaluation is not only paramount to judicious fault inference but it is also central to gaining the trust and buy-in of system users who ultimately can apply fault detection information to actually fix and improve building operations.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>