<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T00:36:54Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/61615" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/61615</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Jung-Hoon Chun.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Wong, Eehern J</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-03-07T15:24:04Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-03-07T15:24:04Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/61615</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">704740067</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 147-151).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Polydimethylsiloxane (PDMS) is an important thermosetting elastomer for microfluidic devices because it can replicate nano-scale features and form flexible membranes useful for microactuation. PDMS is used extensively in research environments because it is readily available and biocompatible. However, the prototyping process is too slow for volume manufacturing. The dominant rate limiting step is curing, and high temperature cures used to speed the curing process have adverse effects on the shape of the parts produced. This thesis examines the PDMS cure process and presents a methodology to intelligently design faster cure processes without compromising the quality of parts produced. The first part of this thesis applies statistical mechanics to relate the time evolution of cure with the modulus of elasticity. This enables mechanical testing strategies to be used in situ to monitor the extent of cure, which is important to determine the critical gel point and quantify when the cure process is complete. The gel point describes when PDMS first transitions from a liquid to a solid, and is important for modeling shrinkage and warpage. A novel heated microindentation setup is designed to monitor curing of thin PDMS films, and experimentally validate the theory. The second part of this thesis presents a model for final PDMS shrinkage and warpage using the gel point. Gelation is spatially and temporally distributed, and temperature at the gel point has a direct impact on the shrinkage and warpage observed. The model is validated with experimental data. Since gel temperature is the only parameter to affect shrinkage and curvature, the cure process is accelerated after the gel point without affecting dimensional quality. Increasing the process temperature immediately following gelation is indeed shown to decrease the current cure process time by a factor of five, while maintaining comparable quality. Tolerances on shrinkage and curvature can be used with these models to determine the gel temperatures required, and design multi-temperature processes that speed the cure process.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Eehern J. Wong.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">151p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Modeling and control of rapid cure in polydimethylsiloxane (PDMS) for microfluidic device applications</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Modeling and control of rapid cure in PDMS for microfluidic device applications</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="6b11d5a8-758e-42e0-9600-c5db1bc14cf8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Modeling and control of rapid cure in polydimethylsiloxane (PDMS) for microfluidic device applications&lt;/Title>
   	&lt;Subtitle>Modeling and control of rapid cure in PDMS for microfluidic device applications&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wong, Eehern J&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Polydimethylsiloxane (PDMS) is an important thermosetting elastomer for microfluidic devices because it can replicate nano-scale features and form flexible membranes useful for microactuation. PDMS is used extensively in research environments because it is readily available and biocompatible. However, the prototyping process is too slow for volume manufacturing. The dominant rate limiting step is curing, and high temperature cures used to speed the curing process have adverse effects on the shape of the parts produced. This thesis examines the PDMS cure process and presents a methodology to intelligently design faster cure processes without compromising the quality of parts produced. The first part of this thesis applies statistical mechanics to relate the time evolution of cure with the modulus of elasticity. This enables mechanical testing strategies to be used in situ to monitor the extent of cure, which is important to determine the critical gel point and quantify when the cure process is complete. The gel point describes when PDMS first transitions from a liquid to a solid, and is important for modeling shrinkage and warpage. A novel heated microindentation setup is designed to monitor curing of thin PDMS films, and experimentally validate the theory. The second part of this thesis presents a model for final PDMS shrinkage and warpage using the gel point. Gelation is spatially and temporally distributed, and temperature at the gel point has a direct impact on the shrinkage and warpage observed. The model is validated with experimental data. Since gel temperature is the only parameter to affect shrinkage and curvature, the cure process is accelerated after the gel point without affecting dimensional quality. Increasing the process temperature immediately following gelation is indeed shown to decrease the current cure process time by a factor of five, while maintaining comparable quality. Tolerances on shrinkage and curvature can be used with these models to determine the gel temperatures required, and design multi-temperature processes that speed the cure process.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>