<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T21:22:58Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/62536" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/62536</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Rohit N. Karnik.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Raafat, Mohamed Salem</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-04-25T16:15:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-04-25T16:15:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/62536</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">712950916</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 54-57).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">In this thesis, a new microfluidic device is presented for sorting of deformable particles based on the hydrodynamic resistance induced in a microchannel. Hydrodynamic resistance can be related to physical properties, including size and deformability of the particle, and can also be influenced by particle-wall interactions, hence allowing sorting based on any of these characteristics. This device could find application in cell sorting and bioseparation for therapeutics, research, and point-of-care diagnostics, as well as in sorting of droplets and emulsions for research and industrial applications (e.g., pharmaceutics, food industry, etc.). The device design is carried out using an equivalent resistance model, and numerical simulations are used to validate the design. The device is fabricated in PDMS, flow velocities are characterized using particle streak velocimetry, and sorting experiments are conducted to sort deformable gelatin particles according to size, and droplets of water and glycerol according to deformability. A sorting resolution of approximately 1 pm was obtained when sorting based on size, and droplets of water and glycerol were sorted into separate streams when sorting based on deformability. The main strength of the device over existing technology lies in its simplicity: sorting is carried out passively in the microfluidic circuit, eliminating the need for additional detection or sorting modules. Moreover, the device could be easily customized to change the sorting parameter or the sorting threshold, and multiple devices can be combined in parallel (to increase throughput) or in series (to increase resolution).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Mohamed Salem Raafat.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">57 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Self-sorting of deformable particles in a microfluidic circuit</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="f9e1787a-ddc2-4ea7-92c8-6215053f5849">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Self-sorting of deformable particles in a microfluidic circuit&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Raafat, Mohamed Salem&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>In this thesis, a new microfluidic device is presented for sorting of deformable particles based on the hydrodynamic resistance induced in a microchannel. Hydrodynamic resistance can be related to physical properties, including size and deformability of the particle, and can also be influenced by particle-wall interactions, hence allowing sorting based on any of these characteristics. This device could find application in cell sorting and bioseparation for therapeutics, research, and point-of-care diagnostics, as well as in sorting of droplets and emulsions for research and industrial applications (e.g., pharmaceutics, food industry, etc.). The device design is carried out using an equivalent resistance model, and numerical simulations are used to validate the design. The device is fabricated in PDMS, flow velocities are characterized using particle streak velocimetry, and sorting experiments are conducted to sort deformable gelatin particles according to size, and droplets of water and glycerol according to deformability. A sorting resolution of approximately 1 pm was obtained when sorting based on size, and droplets of water and glycerol were sorted into separate streams when sorting based on deformability. The main strength of the device over existing technology lies in its simplicity: sorting is carried out passively in the microfluidic circuit, eliminating the need for additional detection or sorting modules. Moreover, the device could be easily customized to change the sorting parameter or the sorting threshold, and multiple devices can be combined in parallel (to increase throughput) or in series (to increase resolution).&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>