<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T01:31:59Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/67616" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/67616</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Linda G. Griffith and Jeffrey T. Borenstein.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Inamdar, Niraj K</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-12-09T21:33:01Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-12-09T21:33:01Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/67616</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">765928975</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Page 126 blank. Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 121-125).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Microfluidic devices form an important class of analytical platforms that have found wide use in the biomedical sciences. In particular, they have been used in cell culture systems, where they are used to monitor cell behavior in various environments. One challenge that has emerged, however, is the ability for a microfluidic device to uniformly deliver soluble factors to a given culture of cells without subjecting the cells to hydrodynamic shear stresses that could potentially alter their behavior in an unpredictable or undesirable way. This is especially true for a number of cell types, and striking a balance between solute transport and shear stress remains the subject of active research. In this thesis, we will consider a membrane bilayer device configuration in which the transport of a solute to a cell population is achieved by flowing solute through a proximate channel separated from the culture channel by a membrane and seek to characterize some of its hydrodynamic and transport characteristics. It will be shown analytically that this configuration affords greater flexibility over a more traditional single-channel setup, in terms of control over solute transport and applied shear. We will also discuss some topics related to the flow fields within such devices, as well as the fabrication and implementation of the bilayer microfluidic device in an experimental setting.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Niraj K. Inamdar.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">126 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Analysis and implementation of the bilayer microfluidic geometry</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ddd99af9-3e77-4f6f-83f9-18c486f0b850">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Analysis and implementation of the bilayer microfluidic geometry&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Inamdar, Niraj K&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Microfluidic devices form an important class of analytical platforms that have found wide use in the biomedical sciences. In particular, they have been used in cell culture systems, where they are used to monitor cell behavior in various environments. One challenge that has emerged, however, is the ability for a microfluidic device to uniformly deliver soluble factors to a given culture of cells without subjecting the cells to hydrodynamic shear stresses that could potentially alter their behavior in an unpredictable or undesirable way. This is especially true for a number of cell types, and striking a balance between solute transport and shear stress remains the subject of active research. In this thesis, we will consider a membrane bilayer device configuration in which the transport of a solute to a cell population is achieved by flowing solute through a proximate channel separated from the culture channel by a membrane and seek to characterize some of its hydrodynamic and transport characteristics. It will be shown analytically that this configuration affords greater flexibility over a more traditional single-channel setup, in terms of control over solute transport and applied shear. We will also discuss some topics related to the flow fields within such devices, as well as the fabrication and implementation of the bilayer microfluidic device in an experimental setting.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>