<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T15:40:26Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/68459" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/68459</identifier><datestamp>2022-01-13T07:53:45Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Lawrence L. Wald.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Witzel, Thomas, Ph. D. Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Harvard University--MIT Division of Health Sciences and Technology</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-01-12T19:29:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-01-12T19:29:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/68459</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">769129139</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2011.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Magnetic resonance imaging (MRI) has demonstrated the potential for non-invasive mapping of structure and function (fMRI) in the human brain. In this thesis, we propose a series of methodological developments towards improved fMRI of auditory processes. First, the inefficiency of standard fMRI that acquires brain volumes one slice at a time is addressed. The proposed single-shot method is capable, for the first time, of imaging the entire brain in a single-acquisition while still maintaining adequate spatial resolution for fMRI. This method dramatically increases the temporal resolution of fMRI (20 fold) and improves sampling efficiency as well as the ability to discriminate against detrimental physiological noise. To accomplish this it exploits highly accelerated parallel imaging techniques and MRI signal detection with a large number of coil elements. We then address a major problem in the application of fMVIRI to auditory studies. In standard fMRI, loud acoustic noise is generated by the rapid switching of the gradient magnetic fields required for image encoding, which interferes with auditory stimuli and enforces inefficient and slow sampling strategies. We demonstrate a fMRI method that uses parallel imaging and redesigned gradient waveforms to both minimize and slow down the gradient switching to substantially reduce acoustic noise while still enabling rapid acquisitions for fMRI. Conventional fMRI is based on a hemodynamic response that is secondary to the underlying neuronal activation. In the final contribution of this thesis, a novel image contrast is introduced that is aimed at the direct observation of neuronal magnetic fields associated with functional activation. Early feasibility studies indicate that the imaging is sensitive to oscillating magnetic fields at amplitudes similar to those observed by magnetoencephalography.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Thomas Witzel.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">99 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Harvard University--MIT Division of Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Methods for functional brain imaging</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="3fb3d967-eb8c-4163-91d0-3ddc82be4668">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Methods for functional brain imaging&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Witzel, Thomas, Ph. D. Massachusetts Institute of Technology&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Harvard University--MIT Division of Health Sciences and Technology.&lt;/Keyword>
   	&lt;Abstract>Magnetic resonance imaging (MRI) has demonstrated the potential for non-invasive mapping of structure and function (fMRI) in the human brain. In this thesis, we propose a series of methodological developments towards improved fMRI of auditory processes. First, the inefficiency of standard fMRI that acquires brain volumes one slice at a time is addressed. The proposed single-shot method is capable, for the first time, of imaging the entire brain in a single-acquisition while still maintaining adequate spatial resolution for fMRI. This method dramatically increases the temporal resolution of fMRI (20 fold) and improves sampling efficiency as well as the ability to discriminate against detrimental physiological noise. To accomplish this it exploits highly accelerated parallel imaging techniques and MRI signal detection with a large number of coil elements. We then address a major problem in the application of fMVIRI to auditory studies. In standard fMRI, loud acoustic noise is generated by the rapid switching of the gradient magnetic fields required for image encoding, which interferes with auditory stimuli and enforces inefficient and slow sampling strategies. We demonstrate a fMRI method that uses parallel imaging and redesigned gradient waveforms to both minimize and slow down the gradient switching to substantially reduce acoustic noise while still enabling rapid acquisitions for fMRI. Conventional fMRI is based on a hemodynamic response that is secondary to the underlying neuronal activation. In the final contribution of this thesis, a novel image contrast is introduced that is aimed at the direct observation of neuronal magnetic fields associated with functional activation. Early feasibility studies indicate that the imaging is sensitive to oscillating magnetic fields at amplitudes similar to those observed by magnetoencephalography.&lt;/Abstract>