<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T12:52:51Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/68699" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/68699</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Markus Zahn.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Snively, Michael John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-01-30T15:22:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-01-30T15:22:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/68699</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">773702981</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This electronic version was submitted by the student author.  The certified thesis is available in the Institute Archives and Special Collections.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from student submitted PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 105).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The mechanisms that lead to bulk  flow within a ferrofluid-filled container subjected to a rotating uniform magnetic field are experimentally studied. There are two prevailing theories: spin diffusion theory and  flow due to non-uniformities in magnetic field within the ferrofluid due to nonuniform demagnetizing factors. This research sought to confirm previous measurements that indicated demagnetizing factors are the primary cause of bulk ferrofluid  flow. Flattened spherical containers of various volumes, and thus different demagnetizing factors, were filled with EFH1 oil-based ferrofluid and subjected to a uniform rotating magnetic field of varying conditions (rotation direction and field strength). The shapes and magnitudes of the velocity profiles measured by an ultrasound velocimeter system differed between containers, indicating that demagnetizing factors did affect  flow. The complicated flows within the flattened spheres that affected both the shape and magnitude of the  flow velocity prevented a direct magnitude comparison between profiles but the flows differed enough to safely conclude that spatial non-uniformities within the  fluid likely caused the bulk flow of  fluid in the uniform rotating magnetic field.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Michael John Snively.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">105 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by &#xd;
copyright. They may be viewed from this source for any purpose, but &#xd;
reproduction or distribution in any format is prohibited without written &#xd;
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Effects of demagnetizing factors on transient motion of ferrofluid in a uniform rotating magnetic field</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b72b902a-7ce5-4cb0-9297-d42709efd3e1">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Effects of demagnetizing factors on transient motion of ferrofluid in a uniform rotating magnetic field&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Snively, Michael John&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The mechanisms that lead to bulk  flow within a ferrofluid-filled container subjected to a rotating uniform magnetic field are experimentally studied. There are two prevailing theories: spin diffusion theory and  flow due to non-uniformities in magnetic field within the ferrofluid due to nonuniform demagnetizing factors. This research sought to confirm previous measurements that indicated demagnetizing factors are the primary cause of bulk ferrofluid  flow. Flattened spherical containers of various volumes, and thus different demagnetizing factors, were filled with EFH1 oil-based ferrofluid and subjected to a uniform rotating magnetic field of varying conditions (rotation direction and field strength). The shapes and magnitudes of the velocity profiles measured by an ultrasound velocimeter system differed between containers, indicating that demagnetizing factors did affect  flow. The complicated flows within the flattened spheres that affected both the shape and magnitude of the  flow velocity prevented a direct magnitude comparison between profiles but the flows differed enough to safely conclude that spatial non-uniformities within the  fluid likely caused the bulk flow of  fluid in the uniform rotating magnetic field.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>