<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T00:17:26Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/69486" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/69486</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Brian W. Anthony.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Donoghue, Linda (Linda Marie)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-02-29T17:58:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-02-29T17:58:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/69486</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">775600877</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 75-77).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The performance of interdigitated electrodes for impedance measurements is dependent upon the geometric design of the electrode pattern and can be significantly impacted by manufactured variability or defects. For processes which rely on precise electrode performance, such as the biochemical assay in the Daktari CD4 diagnostic system, it is necessary to minimize variation through robust design and quality control. Interdigitated electrode design was investigated to identify design strategies which maximize electrode sensitivity and minimize performance variability in produced parts, while potentially reducing the complexity of quality testing. Several configurations were developed to address these goals by increasing the sensing region for a specified electrode area and creating designs which can be more easily manufactured with low variability. Design modifications included alterations to interdigitated finger orientation, finger geometry, and gap width. Test findings indicate that optimal designs contain narrow gap widths with electrode fingers parallel to the longest dimension of the electrode. These benefits may be further enhanced by replacing straight finger edges with geometrical features, such as scalloped edges. The design changes identified can be used to improve interdigitated electrode performance for an array of applications and reduce performance variability caused by variation in the manufacturing process.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Linda Donoghue.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">77 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design of a micro-interdigitated electrode for impedance measurement performance in a biochemical assay</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ce3b78ac-4e5e-4648-b2aa-ff65a5e12f93">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design of a micro-interdigitated electrode for impedance measurement performance in a biochemical assay&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Donoghue, Linda (Linda Marie)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The performance of interdigitated electrodes for impedance measurements is dependent upon the geometric design of the electrode pattern and can be significantly impacted by manufactured variability or defects. For processes which rely on precise electrode performance, such as the biochemical assay in the Daktari CD4 diagnostic system, it is necessary to minimize variation through robust design and quality control. Interdigitated electrode design was investigated to identify design strategies which maximize electrode sensitivity and minimize performance variability in produced parts, while potentially reducing the complexity of quality testing. Several configurations were developed to address these goals by increasing the sensing region for a specified electrode area and creating designs which can be more easily manufactured with low variability. Design modifications included alterations to interdigitated finger orientation, finger geometry, and gap width. Test findings indicate that optimal designs contain narrow gap widths with electrode fingers parallel to the longest dimension of the electrode. These benefits may be further enhanced by replacing straight finger edges with geometrical features, such as scalloped edges. The design changes identified can be used to improve interdigitated electrode performance for an array of applications and reduce performance variability caused by variation in the manufacturing process.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>