<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T00:33:33Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/71312" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/71312</identifier><datestamp>2022-01-13T07:54:12Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Timothy E. Johnson.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Benton, Charles Crisp</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Architecture.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Architecture</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-07-02T15:16:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-07-02T15:16:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">1979</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">1979</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/71312</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">06860277</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Arch.)--Massachusetts Institute of Technology, Dept. of Architecture, 1979.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The electric utilities in the United States are faced with continued rapid growth in electrical demand. The traditional response to growth in demand has been the expansion of generating capacity. However, economic, environmental, and scheduling constraints will combine to make adequate expansion difficult, if not impossible, in the 1980's. This thesis examines load management as an alternative to the proliferation of generating plants. This path is illustrated by the development of an air conditioning system designed to displace power consumption in commercial buildings from peak to off-peak periods. The urban domestic utilities face their peak loads during the summer air conditioning season. The displacement of daytime air conditioning will therefore reduce the utilities' annual peak load. The proposed air conditioning system uses off-peak power, and conventional mechanical equipment, to recharge a thermal energy storage system. The thermal storage medium is a sodium sulfate-based phase change material (PCM) enclosed in small thin bags. These bags are distributed throughout the ceiling plane of the building; supported by special ceiling tiles. At night, the PCM is charged by chilling the plenum space; during the day, the PCM, in direct contact with the occupied space, removes sensible heat gains by melting. System components are described by their programmatic requirements. The performance of the proposed off-peak cooling system was simulated under a variety of conditions involving interior zone commercial office spaces. It was found, using thermal comfort criteria, that the system performed well using a PCM set point temperature of 67°F. Under the operating parameters established, the simulations indicated that the energy flow rates were adequate for successful system performance. Finally, it was determined that the system can provide immediate savings through customer demand leveling and increased chiller efficiency. However, the major potential for savings will relate to anticipated utility incentives for off-peak electrical use.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">Charles C. Benton</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Arch.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">147 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Architecture.</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="lcsh" lang="en_US">Air conditioning</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="lcsh" lang="en_US">Heating</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="lcsh" lang="en_US">Ventilation</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="lcsh" lang="en_US">Buildings Energy conservation</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Off-peak cooling using phase change material</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="900ba033-0534-47fd-958e-b190da92948a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Off-peak cooling using phase change material&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>1979&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Benton, Charles Crisp&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Architecture.&lt;/Keyword>
   	&lt;Abstract>The electric utilities in the United States are faced with continued rapid growth in electrical demand. The traditional response to growth in demand has been the expansion of generating capacity. However, economic, environmental, and scheduling constraints will combine to make adequate expansion difficult, if not impossible, in the 1980&amp;apos;s. This thesis examines load management as an alternative to the proliferation of generating plants. This path is illustrated by the development of an air conditioning system designed to displace power consumption in commercial buildings from peak to off-peak periods. The urban domestic utilities face their peak loads during the summer air conditioning season. The displacement of daytime air conditioning will therefore reduce the utilities&amp;apos; annual peak load. The proposed air conditioning system uses off-peak power, and conventional mechanical equipment, to recharge a thermal energy storage system. The thermal storage medium is a sodium sulfate-based phase change material (PCM) enclosed in small thin bags. These bags are distributed throughout the ceiling plane of the building; supported by special ceiling tiles. At night, the PCM is charged by chilling the plenum space; during the day, the PCM, in direct contact with the occupied space, removes sensible heat gains by melting. System components are described by their programmatic requirements. The performance of the proposed off-peak cooling system was simulated under a variety of conditions involving interior zone commercial office spaces. It was found, using thermal comfort criteria, that the system performed well using a PCM set point temperature of 67°F. Under the operating parameters established, the simulations indicated that the energy flow rates were adequate for successful system performance. Finally, it was determined that the system can provide immediate savings through customer demand leveling and increased chiller efficiency. However, the major potential for savings will relate to anticipated utility incentives for off-peak electrical use.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>