<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T07:25:02Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/74928" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/74928</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Benjamin J. Vakoc.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Nam, Ahhyun</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-11-19T19:19:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-11-19T19:19:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/74928</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">815767739</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 65-67).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The abnormal structure of cutaneous capillaries is associated with many skin diseases including skin cancer and port wine stain. Consequently, the demand for an imaging modality that can provide non-invasive visualization of capillary level blood flow is high. The major challenge in such imaging is to achieve high resolution and great flow sensitivity over a sufficient depth. Numerous imaging techniques derived from optical coherence tomography have provided a technical breakthrough and produced promising images of capillary networks of retina and brain tumors. However, these modalities have never been applied in clinical dermatological studies. This thesis illustrates the process of design and complete construction of an optical frequency domain imaging (OFDI) system for dermal vasculature imaging that can be used in a clinical environment. The system consists of optical hardware, electronics, and a microscope; every part is contained in a portable cart that can be readily carried to a clinic. The optical subsystem includes a wavelength-swept laser source, a fiber optic interferometer with a delay stage and a polarization-sensitive balanced receiver. All power supplies, control drivers and monitoring circuits are integrated and enclosed in a case with a control interface. The microscope is attached to an articulating arm to be positioned as desired while the patient sits at ease. The system performance is summarized as 10 [mu]m resolution with frame rate of 100 frames per second. Further studies, in collaboration with dermatologists, will involve imaging the vascular structure of port wine stain lesions and investigating their correlation to laser treatment.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Ahhyun Nam.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">67 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Development of a coherent optical imaging system for clinical dermatology</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="80ffe397-e4a7-4340-873a-e84bacb99656">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Development of a coherent optical imaging system for clinical dermatology&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2012&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Nam, Ahhyun&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The abnormal structure of cutaneous capillaries is associated with many skin diseases including skin cancer and port wine stain. Consequently, the demand for an imaging modality that can provide non-invasive visualization of capillary level blood flow is high. The major challenge in such imaging is to achieve high resolution and great flow sensitivity over a sufficient depth. Numerous imaging techniques derived from optical coherence tomography have provided a technical breakthrough and produced promising images of capillary networks of retina and brain tumors. However, these modalities have never been applied in clinical dermatological studies. This thesis illustrates the process of design and complete construction of an optical frequency domain imaging (OFDI) system for dermal vasculature imaging that can be used in a clinical environment. The system consists of optical hardware, electronics, and a microscope; every part is contained in a portable cart that can be readily carried to a clinic. The optical subsystem includes a wavelength-swept laser source, a fiber optic interferometer with a delay stage and a polarization-sensitive balanced receiver. All power supplies, control drivers and monitoring circuits are integrated and enclosed in a case with a control interface. The microscope is attached to an articulating arm to be positioned as desired while the patient sits at ease. The system performance is summarized as 10 [mu]m resolution with frame rate of 100 frames per second. Further studies, in collaboration with dermatologists, will involve imaging the vascular structure of port wine stain lesions and investigating their correlation to laser treatment.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>