<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T23:57:14Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/74953" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/74953</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Dan D. Frey and Conor James Walsh.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Wu, Faye Y</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-11-19T19:21:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-11-19T19:21:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/74953</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">816655958</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 116-118).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This thesis describes the design of a guidance device for faster and more accurate targeting of multiple probes during cryoablation and other percutaneous interventions performed in closed bore magnetic resonance (MR) imaging systems. The device is intended to be mounted onto a Siemens 110 mm MR loop coil that rests on the patient and contains a cable driven two-degree-of- freedom spherical mechanism that orientates the intervention probes about a remote center of motion located 15 mm above the skin entry point. A carriage, pulled by strong and low stretch cables, can position up to three intervention probes as it travels on a rotating hoop. Its motion is constrained by a custom designed roller bearing to minimize friction. A thumbscrew fastened latch allows a probe to be engaged in a guide that constrains the probe along a specific trajectory. The probe can also be disengaged from its track, freeing it to move with respiration and enabling the guide to be repositioned for another probe to be inserted. Compact MR compatible piezoelectric motors are used to actuate the system. A prototype was built from 3D printed ABS plastic as a proof of concept. Bench level evaluation demonstrated that each component of the device performs according to the design specifications. The device performance was characterized by analyzing still images taken before and after movement, which yielded sub-degree accuracy, sub-degree repeatability near vertical position, and an incremental step resolution of at least 0.5 degree. Upon further developments of the registration and calibration modules in 3D slicer to interface the robot with image data, evaluation of the device in MRI will be performed.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Faye Y. Wu.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">141 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Multi-probe robotic positioner for cryoablation in MRI</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="5590ede7-29f7-4e8b-8024-1795b92ed37a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Multi-probe robotic positioner for cryoablation in MRI&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2012&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wu, Faye Y&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>This thesis describes the design of a guidance device for faster and more accurate targeting of multiple probes during cryoablation and other percutaneous interventions performed in closed bore magnetic resonance (MR) imaging systems. The device is intended to be mounted onto a Siemens 110 mm MR loop coil that rests on the patient and contains a cable driven two-degree-of- freedom spherical mechanism that orientates the intervention probes about a remote center of motion located 15 mm above the skin entry point. A carriage, pulled by strong and low stretch cables, can position up to three intervention probes as it travels on a rotating hoop. Its motion is constrained by a custom designed roller bearing to minimize friction. A thumbscrew fastened latch allows a probe to be engaged in a guide that constrains the probe along a specific trajectory. The probe can also be disengaged from its track, freeing it to move with respiration and enabling the guide to be repositioned for another probe to be inserted. Compact MR compatible piezoelectric motors are used to actuate the system. A prototype was built from 3D printed ABS plastic as a proof of concept. Bench level evaluation demonstrated that each component of the device performs according to the design specifications. The device performance was characterized by analyzing still images taken before and after movement, which yielded sub-degree accuracy, sub-degree repeatability near vertical position, and an incremental step resolution of at least 0.5 degree. Upon further developments of the registration and calibration modules in 3D slicer to interface the robot with image data, evaluation of the device in MRI will be performed.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>