<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T23:20:26Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/76496" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/76496</identifier><datestamp>2022-01-13T07:54:37Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Richard Lanza.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Erickson, Anna S</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-01-23T19:44:36Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-01-23T19:44:36Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/76496</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">823504611</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2011.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 161-167).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The need for large-size detectors for long-range active interrogation (Al) detection has generated interest in water-based detector technologies. AI is done using external radiation sources to induce fission and to detect, identify, and characterize special nuclear material (SNM) through the gamma rays and neutrons emitted. Long-range applications require detectors with a large solid angle and an ability to significantly suppress lowenergy background from linear electron accelerators. Water Cherenkov Detectors (WCD) were selected because of their transportability, scalability, and an inherent energy threshold. The main objective of this thesis was to design a large-size WCD capable of detecting gamma rays and to demonstrate particle energy discrimination ability. WCD was modeled in detail using Geant4 for optimization purposes. The experimental detector is composed of an aluminum body with a high efficiency (98.5%) diffuse reflector. Cherenkov photons are detected with six 8" hemispherical Hamamatsu photomultiplier tubes (PMT). PMTs are calibrated using two monoenergetic LEDs. The detector was shown to successfully detect gamma rays of energies above the Cherenkov threshold. The detector was able to discriminate between various sources, such as ⁶⁰Co and ²³²Th, even though WCD are known for their poor energy resolution. The detector design and analysis was completed, and it was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. One of the accomplishments of this thesis was demonstration of event reconstruction capability of the detector system. A full-detector model was created using Geant4 simulation toolkit. The performance of the detector was predicted using the model and then experimentally verified. The qualitative agreement between the model and the experiment was observed. The event reconstruction was an important part of the detector performance analysis. Post-experimental data processing was done using ROOT.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Anna S. Erickson.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">190 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Remote detection of fissile material : Cherenkov counters for gamma detection</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2fa9407b-6a7e-48e3-bf0c-dc2948089306">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Remote detection of fissile material : Cherenkov counters for gamma detection&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2011&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Erickson, Anna S&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Science and Engineering.&lt;/Keyword>
   	&lt;Abstract>The need for large-size detectors for long-range active interrogation (Al) detection has generated interest in water-based detector technologies. AI is done using external radiation sources to induce fission and to detect, identify, and characterize special nuclear material (SNM) through the gamma rays and neutrons emitted. Long-range applications require detectors with a large solid angle and an ability to significantly suppress lowenergy background from linear electron accelerators. Water Cherenkov Detectors (WCD) were selected because of their transportability, scalability, and an inherent energy threshold. The main objective of this thesis was to design a large-size WCD capable of detecting gamma rays and to demonstrate particle energy discrimination ability. WCD was modeled in detail using Geant4 for optimization purposes. The experimental detector is composed of an aluminum body with a high efficiency (98.5%) diffuse reflector. Cherenkov photons are detected with six 8&amp;quot; hemispherical Hamamatsu photomultiplier tubes (PMT). PMTs are calibrated using two monoenergetic LEDs. The detector was shown to successfully detect gamma rays of energies above the Cherenkov threshold. The detector was able to discriminate between various sources, such as ⁶⁰Co and ²³²Th, even though WCD are known for their poor energy resolution. The detector design and analysis was completed, and it was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. One of the accomplishments of this thesis was demonstration of event reconstruction capability of the detector system. A full-detector model was created using Geant4 simulation toolkit. The performance of the detector was predicted using the model and then experimentally verified. The qualitative agreement between the model and the experiment was observed. The event reconstruction was an important part of the detector performance analysis. Post-experimental data processing was done using ROOT.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>