<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T23:14:04Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/78461" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/78461</identifier><datestamp>2022-01-13T07:54:01Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Kamal Youcef-Toumi and Amro Farid.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Abdelhalim, Hussein Mohamed</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-04-12T19:26:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-04-12T19:26:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/78461</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">834083814</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 52-53).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This thesis investigates the stability effects of the integration of wind power on multi-machine power systems. First, the small-signal stability effects of turbine governors connected to synchronous generators in the presence of large-scale penetration of wind and load power disturbances are analyzed. Results suggest that tuning the turbine governors when wind power generation is present can improve the small-signal stability of an interconnected system. Then, the transient stability effects of integrating doubly-fed induction wind turbine generators through different transmission line configurations and at different buses are analyzed. Results show that connecting the wind through transmission lines and to different buses introduces a delay in the oscillatory response of the synchronous generator speed, and bus voltage oscillations are also affected. Results also show that there is no significant effect on the base cases when using different interconnection voltages to connect the wind. Overall, the results can be used by power system operators when making decisions on turbine governor tuning and transmission line configurations when connecting wind farms to existing power systems while optimizing for small-signal and transient stability response.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Hussein Mohamed Abdelhalim.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">53 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Stability effects of frequency controllers and transmission line configurations on power systems with integration of wind power</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Small-signal stability effects of frequency and voltage controllers on power systems with integration of wind power</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c194b44e-71f9-44df-95c6-14fc319f75cd">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Stability effects of frequency controllers and transmission line configurations on power systems with integration of wind power&lt;/Title>
   	&lt;Subtitle>Small-signal stability effects of frequency and voltage controllers on power systems with integration of wind power&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2012&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Abdelhalim, Hussein Mohamed&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>This thesis investigates the stability effects of the integration of wind power on multi-machine power systems. First, the small-signal stability effects of turbine governors connected to synchronous generators in the presence of large-scale penetration of wind and load power disturbances are analyzed. Results suggest that tuning the turbine governors when wind power generation is present can improve the small-signal stability of an interconnected system. Then, the transient stability effects of integrating doubly-fed induction wind turbine generators through different transmission line configurations and at different buses are analyzed. Results show that connecting the wind through transmission lines and to different buses introduces a delay in the oscillatory response of the synchronous generator speed, and bus voltage oscillations are also affected. Results also show that there is no significant effect on the base cases when using different interconnection voltages to connect the wind. Overall, the results can be used by power system operators when making decisions on turbine governor tuning and transmission line configurations when connecting wind farms to existing power systems while optimizing for small-signal and transient stability response.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>