<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T11:00:34Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/78471" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/78471</identifier><datestamp>2022-01-13T07:54:01Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Joel Voldman.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Su, Hao-Wei</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-04-12T19:27:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-04-12T19:27:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/78471</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">834089420</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 86-90).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Dielectrophoresis (DEP), a cell separation technique based on the dielectric properties, has significantly advanced biomedical research in diverse applications ranging from blood stem cells purification to cancer cells isolation from heterogeneous populations. The ability to accurately measure the dielectric properties of individual cells is not only critical for effective sorting applications, but is also advantageous for enhancing the current knowledge of cell biology. This thesis proposes a novel method: the n-DEP spring, which applies an electrical field gradient upon continuously flowing cells to distinguish them based on their individual DEP properties. Specifically, the method uses the equilibrium position originating from the force balance between hydrodynamic and DEP forces to infer the cellular dielectric properties. For thorough DEP characterization, changing different conditions of cells is an essential but time-consuming process which usually takes hours to days. Especially for DEP characterization of time-sensitive events, such as neutrophil activation or cell apoptosis, short characterization time is required. This thesis describes the automation of the fluidic, optics, and electronics components of the DEP characterization system, which shortens the characterization time within an hour. We first demonstrated the automated DEP characterization of a mammalian cell type in thirty-nine conditions within an hour. Subsequently, we characterized the neutrophils with different activation states and successfully found out the right conditions to discriminate the activated neutrophils and non-activated neutrophils. With this system and method, we now have the potential to rapidly screen through a variety of system parameters, and optimize conditions for effective cell sorting.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Hao-Wei Su.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">90 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The development of an automated system for electrical characterization of cells using a novel force balance method</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4f6fc4a1-9cc3-4664-9d98-e7fb9af5afab">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>The development of an automated system for electrical characterization of cells using a novel force balance method&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2012&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Su, Hao-Wei&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Dielectrophoresis (DEP), a cell separation technique based on the dielectric properties, has significantly advanced biomedical research in diverse applications ranging from blood stem cells purification to cancer cells isolation from heterogeneous populations. The ability to accurately measure the dielectric properties of individual cells is not only critical for effective sorting applications, but is also advantageous for enhancing the current knowledge of cell biology. This thesis proposes a novel method: the n-DEP spring, which applies an electrical field gradient upon continuously flowing cells to distinguish them based on their individual DEP properties. Specifically, the method uses the equilibrium position originating from the force balance between hydrodynamic and DEP forces to infer the cellular dielectric properties. For thorough DEP characterization, changing different conditions of cells is an essential but time-consuming process which usually takes hours to days. Especially for DEP characterization of time-sensitive events, such as neutrophil activation or cell apoptosis, short characterization time is required. This thesis describes the automation of the fluidic, optics, and electronics components of the DEP characterization system, which shortens the characterization time within an hour. We first demonstrated the automated DEP characterization of a mammalian cell type in thirty-nine conditions within an hour. Subsequently, we characterized the neutrophils with different activation states and successfully found out the right conditions to discriminate the activated neutrophils and non-activated neutrophils. With this system and method, we now have the potential to rapidly screen through a variety of system parameters, and optimize conditions for effective cell sorting.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>