<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T06:15:14Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/79315" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/79315</identifier><datestamp>2026-06-06T01:04:06Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Brian W. Anthony.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Saber, Aabed (Aabed Saud)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-06-17T19:55:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-06-17T19:55:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2013</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/79315</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">847844992</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng. in Manufacturing)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, February 2013.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 71-73).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">In its lab-on-a-chip product, Daktari Diagnostics utilizes "reagent-filled reservoirs" as a means of storing and delivering the liquid reagent. During the clinical trials of the product, undesired reagent flow patterns (namely, flow anomaly 1 &amp; flow anomaly 2) were noticed. This work focused on optimizing the bonding process of the reagent-filled reservoirs to the backbone. Also, the relationship between the bonding process parameters and the reagent flow pattern was studied in depth. To achieve the objective of this thesis, an experiment was designed in which independent variables were the heat sealing parameters (x, y, z) and accelerated aging and the dependent variables were bond strength and the reagent flow pattern. Experiments showed that optimal Heat Sealing parameters are: parameter x = 4.5, parameter y = 110 and parameter z = 1.5. At the optimal settings of bonding process, the highest bond strength was attained and the reagent flow improved considerably but flow anomalies were not completely resolved. Also, results showed that accelerated aging affected the bond strength negatively. Accelerated aging also affected the flow pattern negatively, but this effect was not statistically significant.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Aabed Saber.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng. in Manufacturing</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">73 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Manufacturability of lab on chip devices : reagent-filled reservoirs bonding process and its effect on reagents flow pattern</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="3f1a7690-2104-45bd-a8a7-e8ec9e1acefa">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Manufacturability of lab on chip devices : reagent-filled reservoirs bonding process and its effect on reagents flow pattern&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2013&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Saber, Aabed (Aabed Saud)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>In its lab-on-a-chip product, Daktari Diagnostics utilizes &amp;quot;reagent-filled reservoirs&amp;quot; as a means of storing and delivering the liquid reagent. During the clinical trials of the product, undesired reagent flow patterns (namely, flow anomaly 1 &amp;amp; flow anomaly 2) were noticed. This work focused on optimizing the bonding process of the reagent-filled reservoirs to the backbone. Also, the relationship between the bonding process parameters and the reagent flow pattern was studied in depth. To achieve the objective of this thesis, an experiment was designed in which independent variables were the heat sealing parameters (x, y, z) and accelerated aging and the dependent variables were bond strength and the reagent flow pattern. Experiments showed that optimal Heat Sealing parameters are: parameter x = 4.5, parameter y = 110 and parameter z = 1.5. At the optimal settings of bonding process, the highest bond strength was attained and the reagent flow improved considerably but flow anomalies were not completely resolved. Also, results showed that accelerated aging affected the bond strength negatively. Accelerated aging also affected the flow pattern negatively, but this effect was not statistically significant.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>