<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T22:20:19Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/79316" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/79316</identifier><datestamp>2026-06-06T01:04:06Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Brian W. Anthony.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Inamdar, Tejas Satish</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-06-17T19:55:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-06-17T19:55:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2013</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2013</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/79316</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">847845731</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng. in Manufacturing)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2013.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 93-94).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The reagent delivery mechanism in a point-of-care, HIV diagnostic, microfluidic device is studied. Reagents held in an aluminum pack are released on the opening of a fluidic seal. Fluidic seals, controlling the flow of reagents, are characterized to reduce anomalies in the desired flow pattern. The nature of the current seal was investigated. Four seal patterns - line hemisphere, line flat, chevron hemisphere and chevron flat were created and tested for reagent delivery using a flow sensor and a force gauge. Preliminary experiments suggested that one of the patterns - "line-flat" - resulted in fewer flow anomalies. A parameter scoping exercise involving sealing process parameters (temperature, time, gap and distance) was performed for the line flat seal. The findings of this research can be divided into three categories - 1) bonding phenomenon in current seals, 2) influence of seal pattern on flow and rupture mechanics and 3) process parameters which result in the least flow anomalies. The current seal is found to be a bond between the exposed aluminum on the lid film and the heat seal coating on the dome film. The two chevron patterns result in large amounts of flow anomalies, the line hemisphere pattern also resulted in some instances of flow anomalies. The line-flat pattern creates a seal with the least flow anomalies. A specific set of temperature, time, gap and distance which minimizes flow anomalies was found. The flow performance of the reservoir improved and delamination decreased as the distance of the seal from the reservoir was reduced. The thesis also develops a model to better understand the deformation of the reagent carrying dome and flow dynamics prior to and following the opening of the seal. The dome deformation model provides a framework for relating volume, delamination and flow rate to the geometry and material properties of the reservoir pack.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Tejas Satish Inamdar.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng. in Manufacturing</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">96 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by &#xd;
copyright. They may be viewed from this source for any purpose, but &#xd;
reproduction or distribution in any format is prohibited without written &#xd;
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Manufacturing of lab-on-a-chip devices : characterizing seals for on-board reagent delivery</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="11dd442c-1daa-41a3-8ab1-f5f186ae31d6">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Manufacturing of lab-on-a-chip devices : characterizing seals for on-board reagent delivery&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2013&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Inamdar, Tejas Satish&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The reagent delivery mechanism in a point-of-care, HIV diagnostic, microfluidic device is studied. Reagents held in an aluminum pack are released on the opening of a fluidic seal. Fluidic seals, controlling the flow of reagents, are characterized to reduce anomalies in the desired flow pattern. The nature of the current seal was investigated. Four seal patterns - line hemisphere, line flat, chevron hemisphere and chevron flat were created and tested for reagent delivery using a flow sensor and a force gauge. Preliminary experiments suggested that one of the patterns - &amp;quot;line-flat&amp;quot; - resulted in fewer flow anomalies. A parameter scoping exercise involving sealing process parameters (temperature, time, gap and distance) was performed for the line flat seal. The findings of this research can be divided into three categories - 1) bonding phenomenon in current seals, 2) influence of seal pattern on flow and rupture mechanics and 3) process parameters which result in the least flow anomalies. The current seal is found to be a bond between the exposed aluminum on the lid film and the heat seal coating on the dome film. The two chevron patterns result in large amounts of flow anomalies, the line hemisphere pattern also resulted in some instances of flow anomalies. The line-flat pattern creates a seal with the least flow anomalies. A specific set of temperature, time, gap and distance which minimizes flow anomalies was found. The flow performance of the reservoir improved and delamination decreased as the distance of the seal from the reservoir was reduced. The thesis also develops a model to better understand the deformation of the reagent carrying dome and flow dynamics prior to and following the opening of the seal. The dome deformation model provides a framework for relating volume, delamination and flow rate to the geometry and material properties of the reservoir pack.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>