<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T11:15:21Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/87948" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/87948</identifier><datestamp>2022-01-13T07:54:01Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">James G. Fujimoto.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Liang, Kaicheng</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-13T22:35:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-13T22:35:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/87948</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">880415856</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2014.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">"February 2014." Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 60-69).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A forward viewing fiber optic-based imaging probe device was designed and constructed for use with ultrahigh speed optical coherence tomography in the human gastrointestinal tract. The light source was a MEMS-VCSEL at 1300 nm wavelength running at 300 kHz sweep rate, giving an effective A-line rate of 600 kHz. Data was acquired with a 1.8 GS/s A/D card optically clocked by a maximum fringe frequency of 1 GHz. The optical beam from the probe was scanned by a freely deflecting optical fiber that was mounted proximally on a piezoelectric tubular actuator, which was electrically driven in two perpendicular dimensions to produce a spiral scan pattern. The probe has a 3.3 mm outer diameter and is intended for endoscopic imaging. Multiple optical systems were designed to enable microscopic imaging at variable fields. The probe could also be electrically zoomed by tuning the driving voltage to the piezoelectric actuator, reducing the deflection range of the scanning fiber and thus the scanned field. The optical and mechanical design of the probe was optimized for both axial and transverse compactness.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Kaicheng Liang.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">69 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Forward viewing OCT endomicroscopy</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Forward viewing optical coherence tomography endomicroscopy</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Forward viewing Fourier-domain optical coherence tomography (FDOCT) endomicroscopy.</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="0737964a-5621-4ea3-80da-36e7da253874">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Forward viewing OCT endomicroscopy&lt;/Title>
   	&lt;Subtitle>Forward viewing optical coherence tomography endomicroscopy&lt;/Subtitle>
   	&lt;Subtitle>Forward viewing Fourier-domain optical coherence tomography (FDOCT) endomicroscopy.&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liang, Kaicheng&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>A forward viewing fiber optic-based imaging probe device was designed and constructed for use with ultrahigh speed optical coherence tomography in the human gastrointestinal tract. The light source was a MEMS-VCSEL at 1300 nm wavelength running at 300 kHz sweep rate, giving an effective A-line rate of 600 kHz. Data was acquired with a 1.8 GS/s A/D card optically clocked by a maximum fringe frequency of 1 GHz. The optical beam from the probe was scanned by a freely deflecting optical fiber that was mounted proximally on a piezoelectric tubular actuator, which was electrically driven in two perpendicular dimensions to produce a spiral scan pattern. The probe has a 3.3 mm outer diameter and is intended for endoscopic imaging. Multiple optical systems were designed to enable microscopic imaging at variable fields. The probe could also be electrically zoomed by tuning the driving voltage to the piezoelectric actuator, reducing the deflection range of the scanning fiber and thus the scanned field. The optical and mechanical design of the probe was optimized for both axial and transverse compactness.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>