<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T08:50:05Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/92167" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/92167</identifier><datestamp>2026-06-16T18:55:10Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Paster, Eli (Eli Travis)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-12-08T18:53:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-12-08T18:53:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/92167</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">897133668</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2014.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 150-154).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Gas chromatography is one of the most widely used analytical chemistry techniques for separating and analyzing chemical compounds. Chromatographic methods are used to identify constituent species within a compound and determine the purity and relative concentrations of those species. Current gas chromatographs are heavy, bench top instruments that require large capital expenditures, kilowatt power sources, and trained technicians. Additionally, traditional chromatographic measurements are non-continuous. The first part of this thesis explores the application of stochastic system identification techniques applied to chromatography to enable continuous chromatographic measurements, multiplexing of instrument components, and the ability to optimally tune instrumentation parameters and reduce chromatogram noise. The second part of this thesis explores the development of a miniaturized, standalone gas chromatograph. A handheld, low-cost gas chromatograph has been developed over the course of five device generations, through the implementation of localized heating techniques, on-demand gas generation, and the integration of electrical, mechanical, and chemical processes into a compact volume. Characterization of the device shows comparable operating parameters and performance to equivalent bench top instruments at 0.5% total cost and 0.03% total volume. These contributions reduce the barrier-to-entry for performing high quality chemical measurements, and enable more widespread use of chromatography in monitored, closed-loop, remote operation and automated systems.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Eli Paster.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">154 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Development of a miniature, continuous measurement, stochastic perturbation gas chromatograph</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4b0246b3-73e3-4fc3-bd46-22312b88a5e8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Development of a miniature, continuous measurement, stochastic perturbation gas chromatograph&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Paster, Eli (Eli Travis)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Gas chromatography is one of the most widely used analytical chemistry techniques for separating and analyzing chemical compounds. Chromatographic methods are used to identify constituent species within a compound and determine the purity and relative concentrations of those species. Current gas chromatographs are heavy, bench top instruments that require large capital expenditures, kilowatt power sources, and trained technicians. Additionally, traditional chromatographic measurements are non-continuous. The first part of this thesis explores the application of stochastic system identification techniques applied to chromatography to enable continuous chromatographic measurements, multiplexing of instrument components, and the ability to optimally tune instrumentation parameters and reduce chromatogram noise. The second part of this thesis explores the development of a miniaturized, standalone gas chromatograph. A handheld, low-cost gas chromatograph has been developed over the course of five device generations, through the implementation of localized heating techniques, on-demand gas generation, and the integration of electrical, mechanical, and chemical processes into a compact volume. Characterization of the device shows comparable operating parameters and performance to equivalent bench top instruments at 0.5% total cost and 0.03% total volume. These contributions reduce the barrier-to-entry for performing high quality chemical measurements, and enable more widespread use of chromatography in monitored, closed-loop, remote operation and automated systems.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>