Show simple item record

dc.contributor.advisorRosalind W. Picard.en_US
dc.contributor.authorHernandez Rivera, Javieren_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Architecture. Program in Media Arts and Sciences.en_US
dc.date.accessioned2016-03-25T13:40:17Z
dc.date.available2016-03-25T13:40:17Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/101849
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 206-220).en_US
dc.description.abstractChronic psychological stress carries a wide array of pathophysiological risks, including cardiovascular and cerebrovascular diseases, diabetes, and immune dysregulation. An important step in managing stress, before it becomes chronic, is recognizing precisely when and where it occurs. This thesis creates and evaluates new methods to improve the measurement of stress by leveraging state-of-the-art wearable devices. The first part of the thesis systematically compares gathering self-reported stress levels with head and wrist-worn devices, and compares them to the traditional cellphone in the pocket. In particular, 15 participants were asked to carry these devices during five days of their regular work day and to self-report their emotional state several times a day with our custom experience sampling application. We found that both head and wrist-worn devices significantly outperformed the phone in terms of the amount of answered prompts and the speed to start answering. However, different factors such as interaction types, screen size, and familiarity with the devices affected users' experience and responses. The second part of the thesis develops novel methods to comfortably capture physiological signals associated with the stress response. In particular, 36 participants were asked to carry either a head-worn device, a smartwatch or a smartphone while performing different "still" body postures in a controlled laboratory study. Using the proposed methods, we demonstrated that wearable motion-sensitive sensors inside these devices can capture heart and breathing rates as accurately as FDA-cleared devices from traditional body locations. Furthermore, using the data collected from the 15 participants, we demonstrated that our methods can be opportunistically used in real-life when people are relatively "still. " In our study, for instance, the head-worn device provided accurate heart rate assessments around 20% of the work day. Finally, the third part of the thesis uses supervised learning methods to automatically infer self-reported stress levels from different types of wearable data, including physiological, contextual and behavioral signals. While there is not a one-size-fits-all solution, we found that electrodermal activity, head motion and atmospheric pressure were the more relevant signals across the 15 participants. Furthermore, we characterized many of the challenges that plague the task of real-life stress recognition.en_US
dc.description.statementofresponsibilityby Javier Hernandez Riveraen_US
dc.format.extent220 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectArchitecture. Program in Media Arts and Sciences.en_US
dc.titleTowards wearable stress measurementen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentProgram in Media Arts and Sciences (Massachusetts Institute of Technology)
dc.identifier.oclc942938376en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record