Show simple item record

dc.contributor.advisorMichael P. Short.en_US
dc.contributor.authorSchumaker, Daniel(Daniel C.)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Nuclear Science and Engineering.en_US
dc.date.accessioned2019-07-18T20:31:21Z
dc.date.available2019-07-18T20:31:21Z
dc.date.copyright2018en_US
dc.date.issued2018en_US
dc.identifier.urihttps://hdl.handle.net/1721.1/121808
dc.descriptionThesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2018en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 48-53).en_US
dc.description.abstractProton therapy has yet to implement an in-vivo, real-time, fault-tolerant integral dosimeter. Proposed in this thesis is a conceptual dosimeter to meet such requirements, relying on the radiation-stimulated production of F-centers in alkali halide salts. F-centers are optically active vacancies in the cation-anion lattice filled with a lone electron. These vacancies cause dimming bands in broad-band illumination of the crystal, and the vacancies increase in number in a proportional fashion to the dose received. The experiment proposed here will serve both to measure the dimming quality of various alkali halide salts as well as their decay rate in the dark at room temperature. Once performed, this experiment will demonstrate the feasibility of correlating dose to a real-time color measurement of an implanted alkali halide crystal in a patient undergoing proton radiotherapy. Thus far no such experiments have been performed, however the experimental assembly outlined herein is nearly fully constructed and nearly ready for experimentation upon time of completing this thesis.en_US
dc.description.statementofresponsibilityby Daniel Schumaker.en_US
dc.format.extent53 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleSpectral analysis of integrated F-center feedback dosimeteren_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineeringen_US
dc.identifier.oclc1103608395en_US
dc.description.collectionS.B. Massachusetts Institute of Technology, Department of Nuclear Science and Engineeringen_US
dspace.imported2019-07-18T20:31:18Zen_US
mit.thesis.degreeBacheloren_US
mit.thesis.departmentNucEngen_US