Show simple item record

dc.contributor.advisorElazer R. Edelman.en_US
dc.contributor.authorFeldstein, Michael J. (Michael Jordan)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2008-02-28T15:43:32Z
dc.date.available2008-02-28T15:43:32Z
dc.date.copyright2006en_US
dc.date.issued2006en_US
dc.identifier.urihttp://dspace.mit.edu/handle/1721.1/38327en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/38327
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2006.en_US
dc.descriptionIncludes bibliographical references (p. 131-136).en_US
dc.description.abstractThis thesis explores parameters that govern microvascular occlusion secondary to embolic phenomenon. Bulk and individual properties of microembolic particles were characterized using light microscopy, SEM and optically-based particle analysis. Particulate probability distributions were created from imaging data using Matlab. Size distribution, volume, morphology and chemical properties were quantified using in-vivo and model flow systems to correlate particulate characteristics and occlusive efficacy. This study focused on novel expandable/deformable Polyacrylic acid microspheres (PAA-MS) for use as catheter-deliverable therapeutic emboli. These emboli expand in aqueous media such as blood and remain unexpanded in custom delivery media. The techniques developed to investigate therapeutic microemboli were applied to the analysis of clot dissolution byproducts. PAA-MS expand volumetrically in seconds when placed in aqueous environments. PAA-MS were modified to resist fragmentation based upon failure analysis. Degradation testing demonstrated PAA-MS chemical stability. Charge characteristics inherent to the PAA-MS acid matrix were leveraged to develop low-viscosity media that prevent expansion. Cationic dyes were found that bind the charged matrix within PAA-MS to enhance visualization.en_US
dc.description.abstract(cont.) Unexpanded PAA-MS were delivered through standard catheters and microcatheters at concentrations that induce durable occlusions. Non-expandable microspheres could not be delivered through microcatheters. PAA-MS required less embolic mass to occlude in-vitro flow systems at significantly higher pressures than nonexpandable microspheres. Preliminary biocompatibility tests demonstrated safety and PAA-MS were able to occlude both porcine renal and coronary vasculature in-vivo. An ultrasonic clot dissolution device generated microemboli from synthetic acellular fibrin-only clots and whole blood clots. The average particle size for whole blood clots was less than 100 microns and acellular clots produced larger average emboli than whole blood clots, indicating that cellular components may limit thromboembolic size. The expandable/deformable properties of PAA-MS allow them to traverse microcatheters when unexpanded. Once in blood, PAA-MS expand 140-fold to create a space-filling, pressure resistant occlusion.en_US
dc.description.abstract(cont.) These results have implications for intravascular embolization procedures where smaller catheters minimize vasospasm and allow more precise targeting while stronger occlusions resist occlusive breakdown and associated distal embolization. These embolic improvements could reduce procedural complications while increasing efficacy. Future work will solidify correlations between microembolic properties, microvascular occlusion and tissue infarction.en_US
dc.description.statementofresponsibilityby Michael J. Feldstein.en_US
dc.format.extent136 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/38327en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleQuantitative analysis and modeling of microembolic phenomenaen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc154318904en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record