Show simple item record

dc.contributor.advisorJerome J. Connor.en_US
dc.contributor.authorLeonard, Johan, M. Eng. Massachusetts Institute of Technologyen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.en_US
dc.date.accessioned2008-02-27T20:47:08Z
dc.date.available2008-02-27T20:47:08Z
dc.date.copyright2007en_US
dc.date.issued2007en_US
dc.identifier.urihttp://dspace.mit.edu/handle/1721.1/39269en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/39269
dc.descriptionThesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2007.en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionIncludes bibliographical references (leaves 43-44).en_US
dc.description.abstractIn the recent years, there have been many new skyscrapers built which soar into new heights. The most efficient building system for high-rises has been the framed tube system. However, the framed tube building suffers from shear lag effects which cause a nonlinear distribution of axial stresses along the face of the building. A particular structural system called a diagrid system has caught the attention of the public. The diagrid system is not a new invention. The idea had been around since 1960 and few buildings have been built with the diagrid system. However, the implementation in a larger scale of such tall building was not practical due to high cost related to the difficult node connections. It is only in recent years that the technology has allowed for more reasonable cost of making the diagrid node connections. Despite becoming the new trend in high-rise structures, there are not many technical publications related to diagrid building system. A recent thesis by Moon (2005) studied the various angles of the diagrid to find optimum angle. He has also reviewed the design considerations for diagrid building. This thesis attempts to build on the study by Moon related to the shear lag effect in diagrid building. Diagrid buildings of different configuration are modeled in SAP2000 and analyzed for shear lag effect and structural performance.en_US
dc.description.statementofresponsibilityby Johan Leonard.en_US
dc.format.extent62 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/39269en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectCivil and Environmental Engineering.en_US
dc.titleInvestigation of shear lag effect in high-rise buildings with diagrid systemen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Civil and Environmental Engineering
dc.identifier.oclc170876656en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record