Show simple item record

dc.contributor.advisorKlavs F. Jensen.en_US
dc.contributor.authorDydek, EthelMae Victoriaen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Chemical Engineering.en_US
dc.date.accessioned2012-04-26T18:50:03Z
dc.date.available2012-04-26T18:50:03Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/70401
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 119-123).en_US
dc.description.abstractThe main body of this work considers the design and development of a microfluidic, continuous electrochemical sensor capable of measuring accurate potential differences. The key challenge in creating such a device is the implementation of a miniaturized reference electrode and salt bridge. The purpose of a salt bridge is to allow ionic conduction between the reference and working electrodes while maintaining a physical separation between the two systems. Macro reference electrode and salt bridge techniques are difficult to implement on a micro scale. Instead of attempting to conform one of these techniques to function in a micro system, new methods were developed that take advantage of the conditions in a continuous microfluidic device. In particular, laminar flow and slow relative diffusion times allow for a reference electrode that does not require a physical salt bridge. Ionic conduction is maintained between neighboring reference and analyte streams while slow mixing effectively separates the two systems. Several different device designs were investigated focusing on the prevention of reference electrode contamination. If the reference electrode is chemically contaminated it will no longer behave as expected and can not be used as a reference point. Contamination at the reference electrode was evaluated while varying flow rates and the geometry of the microfluidic device. Mathematical models were simulated in order to understand the mass transport in each device design. Based on these simulations, dimensionless groups were found that defined the dominant physics in each system. These dimensionless numbers were then validated experimentally and numerically over a range of device parameters. Subsequently, operation criteria were developed to ensure that the reference electrode remains stable and uncontaminated. By creating a stable reference electrode on chip, any homogeneous electrochemical system that was previously studied on the macro scale can now be studied continuously in a microfluidic device. A secondary portion of this work investigates the role of surface charge with respect to electrodynamics in a microchannel. As the surface area to volume ratio increases, the concentration of charge at a channel wall may begin to approach the electrolyte concentration in the bulk solution. This phenomenon is studied numerically, with and without convection, in particular as it relates to a possible mechanism for overlimiting current. Additionally, a potential de-ionization device is theorized based on this mechanism along with scaling arguments that can be used to aid device design.en_US
dc.description.statementofresponsibilityby EthelMae Victoria Dydek.en_US
dc.format.extent123 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectChemical Engineering.en_US
dc.titleElectrochemistry and Electrokinetics in Microchannelsen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Chemical Engineering
dc.identifier.oclc784099704en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record