Show simple item record

dc.contributor.advisorAnantha P. Chandrakasan.en_US
dc.contributor.authorDesai, Nachiket Venkappayyaen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2012-12-13T19:20:24Z
dc.date.available2012-12-13T19:20:24Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/75721
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 105-110).en_US
dc.description.abstractBody Area Networks (BANs) are gaining prominence for their capability to revolutionize medical monitoring, diagnosis and treatment. This thesis describes a BAN that uses conductive fabrics (e-textiles) worn by the user to act as a power distribution and data communication network to sensors on the user's body. The network is controlled by a central hub in the form of a Base Station, which can either be a standalone device or can be embedded inside one of the user's portable electronic devices like a cellphone. Specifications for a Physical (PHY) layer and a Medium Access Control (MAC) layer have been developed that make use of the asymmetric energy budgets between the base station and sensor nodes in the network. The PHY layer has been designed to be suitable for the unique needs of such a BAN, namely easy reconfigurability, fault-tolerance and efficient energy and data transfer at low power levels. This is achieved by a mechanism for dividing the network into groups of sensors. The co-designed MAC layer is capable of supporting a wide variety of sensors with different data rate and network access requirements, ranging from EEG monitors to temperature sensors. Circuits have been designed at both ends of the network to transmit, receive and store power and data in appropriate frequency bands. Digital circuits have been designed to implement the MAC protocols. The base station and sensor nodes have been implemented in standard 180nm 1P6M CMOS process, and occupy an area 4.8mm2 and 3.6mm2 respectively. The base station has a minimum power consumption of 2.86mW, which includes the power transmitter, modulation and demodulation circuitry. The sensor nodes can recover up to 33.6paW power to supply to the biomedical signal acquisition circuitry with peak transfer efficiency of 1.2%.en_US
dc.description.statementofresponsibilityby Nachiket Venkappayya Desai.en_US
dc.format.extent110 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleA low power, reconfigurable fabric body area network for healthcare applicationsen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc818357977en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record