Show simple item record

dc.contributor.advisorCharles W. Forsberg.en_US
dc.contributor.authorOloyede, Isaiah Olanrewajuen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.en_US
dc.date.accessioned2013-02-14T15:20:38Z
dc.date.available2013-02-14T15:20:38Z
dc.date.copyright2011en_US
dc.date.issued2011en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/76947
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2011.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 315-325).en_US
dc.description.abstractThe seasonal storage hydrogen peak electricity supply system (SSHPESS) is a gigawatt-year hydrogen storage system which stores excess electricity produced as hydrogen during off-peak periods and consumes the stored hydrogen to produce electricity during peak periods of electricity demand. This thesis investigated and produced high-level system requirements and designs for an SSHPESS. To determine the daily, weekly, and seasonal requirements, analytical and numerical models were developed for all-nuclear, all-wind, and all-solar electricity coupled to storage systems. The electricity demand characteristics were obtained using actual electricity demand data from power grid operators from the North-East and South-West United States (New England, New York, PJM, and California). For an all-nuclear system, it was assumed that electricity was produced at a constant rate. For the wind and solar generating systems, real wind and solar data were obtained using models of wind and solar trough electricity systems. The analyses of the demand characteristics show that for a system containing only base-load plants (all-nuclear electricity systems) with lossless large-scale electricity storage systems, the base-load demand would increase by 50% relative to current electrical infrastructure and 93% of the electricity would be sent directly to customers. About 7% of the annual electricity production would be sent to storage at times of low electricity demand for use at times of high electricity demand. The "7% Nuclear Electricity to Storage Ratio" is applicable to all the power grids considered. Analyses done for inefficient storage systems show that about 11% of the energy produced is sent to storage. The results also show that all-nuclear electricity system requires the least amount of energy storage capacity for seasonal energy storage. As an example, the California grid data is shown below assuming the H2 storage system meets hourly, daily, or weekly energy storage needs.en_US
dc.description.statementofresponsibilityby Isaiah Olanrewaju Oloyede.en_US
dc.format.extent325 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleDesign and evaluation of seasonal storage hydrogen peak electricity supply systemen_US
dc.title.alternativeDesign and evaluation of SSHPESSen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc824616033en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record