Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. Thermal and Mechanical Performance Assessment of a MW-Class Electrical Machine for Aircraft Propulsion

Thermal and Mechanical Performance Assessment of a MW-Class Electrical Machine for Aircraft Propulsion

Thumbnail Image
Download
Name

constant-econst-sm-aeroastro-2026-thesis.pdf

Size

56.31 MB

Format

Adobe PDF

Checksum (MD5)

970508583afa496ddfd57470a0a0a7af

Author(s)
Constant, Evrard J.
Advisor(s)
Spakovszky, Zoltán S.
Date Issued
May 2026
Publisher
Massachusetts Institute of Technology
Abstract
As aviation is responsible for nearly 3.5% of global greenhouse gas emissions [1], electrification has emerged as a potential pathway toward reducing the environmental impact of air transportation. While batteries are often identified as a major bottleneck in electrification, the electrical powertrain introduces thermal, mechanical, and integration challenges that must be overcome to achieve the required performance for aviation. In this context, a megawatt-class electrical machine technology demonstrator was previously developed at the MIT Gas Turbine Laboratory (GTL) [2]. The MW level demonstration couples two identical electrical machines to circulate power. Single machine test campaigns involved rotordynamic characterization and no-load testing, followed by coupled-machine experiments demonstrating stable operation at load [3]. The work presented in this thesis documents the assembly of a fully instrumented demonstrator, with particular focus on the integration and assessment of the thermal management system. Finite-element analyses, complemented by ring-tests on the structure, were conducted to assess the dynamic response of the system across the operating range. Experiments at design speed were carried out, demonstrating stable operation at 12,500 rpm. The losses of the demonstrator at no-load conditions were characterized and the cooling system demonstrated sufficient cooling capability. The experimental results were subsequently used to reconcile the analytical and numerical models, yielding agreement within 2% for pressure-loss predictions and 5.5◦C for temperature estimations. Specific procedures and special tooling were developed to accurately align the two machines. Lastly, preliminary investigations of a liquid-cooled variant were conducted to explore alternative thermal management schemes while preserving the high specific power requirements of the system. The results demonstrate that the thermal management system and the chosen mechanical architecture of the demonstrator meet the design intent, paving the way for testing at 1 MW full-load conditions.
MIT Department
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics
Terms of Use
In Copyright - Educational Use Permitted
https://rightsstatements.org/page/InC-EDU/1.0/
Copyright retained by author(s)
Persistent DSpace Link
https://dspace.mit.edu/handle/1721.1/176806
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.