Show simple item record

dc.contributor.advisorPolina Golland.en_US
dc.contributor.authorOu, Wanmeien_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2006-08-25T18:51:25Z
dc.date.available2006-08-25T18:51:25Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/33856
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.en_US
dc.descriptionIncludes bibliographical references (p. 99-102).en_US
dc.description.abstractFunctional Magnetic Resonant Imaging (fMRI) is a non-invasive imaging technique used to study the brain. Neuroscientists have developed various algorithms to determine which voxels of the images are active. Most of these algorithms, operating on the signal of each voxel separately, are referred to as the voxel-by-voxel detectors. Among those voxel-by-voxel detectors, paired T-test and General Linear Model (GLM) are the most popular. The Mutual Information (MI) based detector has recently been introduced. It is interesting to compare these three detectors' modeling assumptions, as well as their performance, in order to understand their advantages and shortcomings. Due to the low signal-to-noise ratio (SNR), the voxel-by-voxel detectors usually result in fragmented activation pattern, which is not in agreement with our understanding of brain activation. The biological models of brain activation suggest that adjacent locations of the brain tend to be in the same activation state. We take advantage of these models and apply a Markov Random Field (MRF) spatial prior to the statistics provided by the voxel-by-voxel algorithms. MRF has been shown to be able to overcome the effect of over-smoothing, which is the major drawback of the conventional spatial regularization models such as the Gaussian smoothing model.en_US
dc.description.abstract(cont.) We adopt Mean Field, a variational algorithm, to estimate the MRF solution. We show that Mean Field can provide reasonable approximation compared with the exact solver in the case of binary MRFs, while reducing the computations by one to two orders of magnitude in our simulated and real data sets. In addition, unlike the exact solver, it can handle multiple-state MRFs. Inspired by atlas-based segmentation, we further refine the spatial regularization process by incorporating anatomical information, such as segmentation results from Magnetic Resonance Imaging (MRI), into the MRF prior. The extended MRF model encodes both tissue type and activation state. To our knowledge, our approach is the first spatial smoothing method that utilizes anatomical information without cortical surface extraction. To evaluate the smoothing models, we performed ROC and confusion matrix analysis on synthetic data. We also evaluate them by studying their ability to recover activation from significantly shorter time course using real data. Including anatomical information improves detection accuracy for both the Gaussian-smoothing-based detector and the MRF-based detector. The Gaussian-smoothing model provides poor results if we are interested in both positive and negative activation regions in the brain.en_US
dc.description.abstract(cont.) Furthermore, the anatomically guided MRF-based detector improves the detection quality compared with the anatomically guided Gaussian-smoothing-based detector for standard fMRI in standard SNR quality.en_US
dc.description.statementofresponsibilityby Wanmei Ou.en_US
dc.format.extent102 p.en_US
dc.format.extent4948314 bytes
dc.format.extent4952528 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titlefMRI detection with spatial regularizationen_US
dc.title.alternativeFunctional Magnetic Resonant Imaging detection with spatial regularizationen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc66277545en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record