Show simple item record

dc.contributor.advisorJung-Hoon Chun and Nannaji Saka.en_US
dc.contributor.authorMau, Catherine (Catherine K.)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2009-04-29T17:07:22Z
dc.date.available2009-04-29T17:07:22Z
dc.date.copyright2008en_US
dc.date.issued2008en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/45202
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.en_US
dc.descriptionIncludes bibliographical references (leaves 132-135).en_US
dc.description.abstractChemical-mechanical planarization (CMP) is a key process in the manufacture of ultra-large-scale-integrated (ULSI) semiconductor devices. A major concern in CMP is non-uniform planarization, or polishing, at the wafer-scale - primarily as interconnect metal dishing and dielectric erosion. In conventional face-down CMP, the pad is much larger than the wafer and the wafer is always in contact with the pad. Thus, non-uniform polishing rate at the wafer-scale is due to variations in relative velocity, normal pressure, and especially slurry distribution at the wafer/pad interface. Wafer-scale polishing uniformity requirements are expected to be even more stringent in the future as the ULSI technology advances toward larger wafers (450 mm) and ever shrinking feature sizes (< 20 nm). This thesis presents the theory and experimental validation of a novel, face-up CMP architecture proposed for achieving a high degree, better than 95 percent of polishing uniformity at the wafer-scale. The novel design utilizes a small, perforated pad that contacts only a portion of the wafer during CMP. Polishing uniformity is achieved by progressively translating the pad away from the polished to the unpolished regions of the wafer. The theory is based on Preston's Law for material removal rate and an optimal algorithm for pad translation. CMP experiments were conducted on both blanket and patterned wafers to validate the theory. Polishing of blanket wafers by non-translating pads showed that the Preston constant is higher at the center of the pad due to increased slurry flow. Thus, perforations at the pad center were blocked to minimize the variation in Preston constant. Face-up polishing of patterned wafers with the blocked pad showed improved wafer-scale uniformity in material removal rate.en_US
dc.description.abstract(cont.) Dielectric erosion was below 30 nm, less than 5 percent of the interconnect depth, across a 100-mm circular polished region. However, dishing of the wider interconnects was much greater. Nevertheless, the variation in dishing across the 100 [mu]m region was less than 35 nm for linewidths ranging from 2.5 [mu]m to 100 [mu]m , also less than 5 percent. Based on the theory and experimental results, several suggestions for further improving face-up CMP to minimize Cu dishing and dielectric erosion are offered.en_US
dc.description.statementofresponsibilityby Catherine Mau.en_US
dc.format.extent135 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleControl of wafer-scale non-uniformity in chemical-mechanical planarization by face-up polishingen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc301734236en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record