Show simple item record

dc.contributor.advisorXiao-Lin Zhou.en_US
dc.contributor.authorLee, Charles L. (Charles Leon), 1970-en_US
dc.date.accessioned2010-01-07T20:50:12Z
dc.date.available2010-01-07T20:50:12Z
dc.date.copyright1998en_US
dc.date.issued1998en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/50535
dc.descriptionThesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1998.en_US
dc.descriptionIncludes bibliographical references (p. 209-219).en_US
dc.description.abstractNear-threshold boron neutron capture therapy (BNCT) uses proton energies only tens of keV above the (p,n) reaction threshold in lithium in order to reduce the moderation requirements of the neutron source. The goals of this research were to prove the feasibility of this near-threshold concept for BNCT applications, using both calculation and experiment, and design a compact neutron source prototype from these results. This required a multidisciplinary development of methods for calculation of neutron yields, head phantom dosimetry, and accelerator target heat removal. First, a method was developed to accurately calculate thick target neutron yields for both near-threshold and higher energy proton beams, in lithium metal as well as lithium compounds. After these yields were experimentally verified, they were used as neutron sources for Monte Carlo (MCNP) simulations of neutron and photon transport in head phantoms. The theoretical and experimental determination of heat removal from a target backing with multiple fins, as well as numerical calculations of heat deposition profiles based on proton energy loss in target and backing materials, demonstrated that lithium integrity can be maintained for proton beam currents up to 2.5 mA. The final design uses a proton beam energy of 1.95 MeV and has a centerline epithermal neutron flux of 2.2 x 108 n/cm2-sec/mA, an advantage depth of 5.7 cm, an advantage ratio of 4.3, and an advantage depth dose rate of 6.7 RBE-cGy/min/mA, corresponding to an irradiation time of 38 minutes with a 5 mA beam. Moderator, reflector, and shielding weigh substantially less than other accelerator BNCT designs based on higher proton energies, e.g. 2.5 MeV. The near-threshold concept is useful as a portable neutron source for hospital settings, with applications ranging from glioblastomas to melanomas and synovectomy.en_US
dc.description.statementofresponsibilityby Charles L. Lee.en_US
dc.format.extent219 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Engineeringen_US
dc.titleThe design of an intense accelerator-based epithermal neutron beam prototype for BNCT using near-threshold reactionsen_US
dc.title.alternativeDesign of an intense accelerator-based epithermal neutron beam prototype for boron neutron capture therapy using near-threshold reactionsen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineeringen_US
dc.identifier.oclc43080626en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record