dc.contributor.advisorHugh Herr and Ed Boyden.en_US
dc.contributor.authorWang, Jing, M. Eng. Massachusetts Institute of Technologyen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Biological Engineering.en_US
dc.date.accessioned2013-01-07T21:21:37Z
dc.date.available2013-01-07T21:21:37Z
dc.date.copyright2011en_US
dc.date.issued2011en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/76110
dc.descriptionThesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Biological Engineering, 2011.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 59-60).en_US
dc.description.abstractSimilar to biological human ankle, today's commercially available powered ankle-foot prostheses can vary impedance and deliver net positive ankle work. These commercially available prostheses are intrinsically controlled. Users cannot intuitively change ankle controller's behavior to perform movements that are not part of the repetitive walking gait cycle. For example, when transition from level ground walking to descending stairs, user cannot intuitively initiate or control the amount of ankle angle deflexion for a more normative stair descent gait pattern. This paper presents a hybrid controller that adds myoelectric control functionality to an existing intrinsic controller. The system employs input from both mechanical sensors on the ankle as well as myoelectric signals from gastrocnemius muscle of the user. This control scheme lets the user to modulate the gain of command ankle torque upon push off during level ground walking and stair ascent. It also allows the user to interrupt level ground walking control cycle and initiate ankle plantar flexion during stair descent. As a preliminary study, ankle characteristics such as ankle angle and torque were measured and compared to biological ankle characteristics. Results show that the proposed hybrid controller can maintain existing controller's biomimetic characteristics. In addition, it can also recognize to a qualitative extent the intended command torque for ankle push off and user's desire to switch between control modalities for different terrains. The study shows that it is possible and desirable to use neural signals as control signals for prosthetic leg controllers. Keyword: Myoelectric control, powered prosthesis, proportional torque controlen_US
dc.description.statementofresponsibilityby Jing Wang.en_US
dc.format.extent60 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectBiological Engineering.en_US
dc.titleEMG control of prosthetic ankle plantar flexionen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Biological Engineering