Show simple item record

dc.contributor.advisorJohn A. Ochsendorf.en_US
dc.contributor.authorEllowitz, Jonathan Calmanen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Civil and Environmental Engineering.en_US
dc.coverage.spatialn-us-nyen_US
dc.date.accessioned2014-09-19T19:37:14Z
dc.date.available2014-09-19T19:37:14Z
dc.date.copyright2014en_US
dc.date.issued2014en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/89847
dc.descriptionThesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2014.en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionCataloged from student-submitted PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 109-111).en_US
dc.description.abstractThe R. Guastavino Company constructed structural masonry vaults for wings E and H of the Metropolitan Museum of Art, New York (the Museum) between 1910 and 1912. In the early 1960s the Museum relocated the Egyptian and Near- and Far-Eastern galleries to these wings, which in combination with growing numbers of visitors doubled the design live load for the vaults. To accommodate this change, the Museum demolished the Guastavino vaults and replaced them with steel beams even though consulting engineers had not performed a thorough structural assessment prior to demolition. The vaults were a part of a landmark McKim, Mead and White building and warranted appropriate analysis to determine their capacity under increased loading demand. This thesis investigates both history and structural analysis. Primary sources reveal that the consulting engineers hired by the Museum were unfamiliar with the structural analysis of unreinforced masonry vaults, leading to the decision to demolish them. These historical events contextualize the quantitative focus of the thesis, which is to provide engineers with accessible techniques to structurally assess unreinforced masonry systems. This enables decisions based on evidence rather than a lack of comprehension of structural behavior. Three important assumptions about masonry behavior are adopted: Masonry has no tensile strength, it has unlimited compression capacity, and it will not fail from sliding between blocks or segments. With these assumptions, masonry analysis is primarily a problem of stability rather than elasticity. Analytical equilibrium and graphical techniques are used to determine vault stability under dead and live loading. Two vaults are investigated: A scaled Guastavino vault built for a recent exhibit, and a representative cross-vault from wing H of the Museum. Two methods of modeling structural behavior are used for each analysis technique: The triangle-arch and sliced parallel arches methods. Analysis shows that the Museum vaults had the capacity to resist the increased live load.en_US
dc.description.statementofresponsibilityby Jonathan Calman Ellowitz.en_US
dc.format.extent131 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectCivil and Environmental Engineering.en_US
dc.titleStructure and history of Guastavino vaulting at the Metropolitan Museum of Arten_US
dc.typeThesisen_US
dc.description.degreeM. Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Civil and Environmental Engineering
dc.identifier.oclc890134232en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record