Show simple item record

dc.contributor.advisorMartin L. Culpepper.en_US
dc.contributor.authorBarraza, Raulen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2015-09-29T18:55:08Z
dc.date.available2015-09-29T18:55:08Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/98952
dc.descriptionThesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (page 49).en_US
dc.description.abstractUltramicrotomy is the process of cutting specimens into submicron-thickness slices for subsequent imaging using a scanning electron microscope (SEM). Ultramicrotomes, devices that employ this process, have incorporated oscillations into this process to reduce the damage done on each slice. Extensive research has been made in trying to identify the appropriate settings: frequency, amplitude of cut, and feed speed, to maximize the reduction of this damage. Currently, however, there exists no research that tries to understand why the introduction of oscillations provides such a reduction in damage. To understand the mechanics behind oscillatory orthogonal cutting, specifically in ultramicrotomy, the frequency response of a compliant mechanism must be understood. The frequency response of a complaint flexural stage driven by piezoelectric actuator was measured. Using a Linear Variable Differential Transformer (LVDT) and a dynamic signal analyzer via LabView, the frequency response of the stage was measured from 100Hz to 10000Hz. A model was then fitted to the measured response. Using this model, a comparison between a simulated-reference response of the position of the stage to the output response of the model showed that a controller was required to minimize the error in the position of the stage.en_US
dc.description.statementofresponsibilityby Raul Barraza.en_US
dc.format.extent49 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleUnderstanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cuttingen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc921147486en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record