Show simple item record

dc.contributor.advisorK. Dane Wittrup and Linda G. Griffith.en_US
dc.contributor.authorDe Picciotto, Seymouren_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Biological Engineering.en_US
dc.date.accessioned2015-09-29T19:00:26Z
dc.date.available2015-09-29T19:00:26Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/99053
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, Department of Biological Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractInvestigating protein location and concentration is critical to understanding function. Reagentless biosensors, in which a reporting fluorophore is conjugated to a binding scaffold, can detect analytes of interest with high temporal and spatial resolution. However, because these biosensors require laborious empirical screening to develop, their adoption has been limited. Hence, we establish design principles that will facilitate development. In this thesis, we first develop a kinetic model for the dynamic performance of a reagentless biosensor. Using a sinusoidal signal for ligand concentration, our findings suggest that it is optimal to use a binding moiety whose equilibrium dissociation constant matches that of the average predicted input signal, while maximizing both the association rate constant and the dissociation rate constant at the necessary ratio to create the desired equilibrium constant. Although practical limitations constrain the attainment of these objectives, the derivation of these design principles provides guidance for improved reagentless biosensor performance and metrics for quality standards in the development of biosensors. Following these guidelines, we use the human tenth type III fibronectin domain to engineer new binders against several ligands of the EGFR receptor. Using these binders and others, we design and characterize biosensors based on various target analytes, scaffolds and fluorophores. We observe that analytes can harbor specific binding pockets for the fluorophore, which sharply increase the fluorescence produced upon binding. Furthermore, we demonstrate that a fluorophore conjugated to locally rigid surfaces possesses lower background fluorescence. Based on these newly identified properties, we design biosensors that produce a 100-fold increase in fluorescence upon binding to analyte, about a 10-fold improvement over the previous best biosensor. In order to improve the methodology of reagentless biosensor design, we establish a method for site-specific labeling of proteins displayed on the surface of yeasts. This procedure allows for the screening of libraries of sensors for binding and fluorescence enhancement simultaneously. Finally, we explore an alternative sensor design, based on competitive inhibition of fluorescence quenching.en_US
dc.description.statementofresponsibilityby Seymour de Picciotto.en_US
dc.format.extent136 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectBiological Engineering.en_US
dc.titleProtein engineering design principles for the development of biosensorsen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Biological Engineering
dc.identifier.oclc921845277en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record