Lifetime Battery Cycle Data For Extreme Operating Conditions
Author(s)
Kumar, Rakesh
Downloadbattery cycle data consisting of README and several CSV files (313.5Mb)
Advisor
Kirtley, James
Metadata
Show full item recordAbstract
Leveraging lab power supplies and electronic loads, 10 AH sealed lead-acid batteries were cycled following extreme operating scenario protocols. These tests were used to determine the impact of such scenarios on battery capacity fade. The data collected may be used to develop improved monitoring strategies, robust battery models, or lifetime elongation protocols by future researchers.
Description
Data related to thesis
Date issued
2019-05-14Keywords
sealed lead-acid battery, high temperature operation, lifetime cycle data, high voltage charging, high current charging, low voltage cutoff