dc.descriptionData related to thesisen_US
dc.description.abstractLeveraging lab power supplies and electronic loads, 10 AH sealed lead-acid batteries were cycled following extreme operating scenario protocols. These tests were used to determine the impact of such scenarios on battery capacity fade. The data collected may be used to develop improved monitoring strategies, robust battery models, or lifetime elongation protocols by future researchers.en_US
dc.subjectsealed lead-acid batteryen_US
dc.subjecthigh temperature operationen_US
dc.subjectlifetime cycle dataen_US
dc.subjecthigh voltage chargingen_US
dc.subjecthigh current chargingen_US
dc.subjectlow voltage cutoffen_US
dc.titleLifetime Battery Cycle Data For Extreme Operating Conditionsen_US