Show simple item record

dc.contributor.authorRohsenow, Warren M.en_US
dc.contributor.authorClark, John A.en_US
dc.contributor.otherMassachusetts Institute of Technology. Division of Industrial Cooperation.en_US
dc.contributor.otherMassachusetts Institute of Technology. Heat Transfer Laboratory.en_US
dc.date.accessioned2011-03-04T23:33:23Z
dc.date.available2011-03-04T23:33:23Z
dc.date.issued1951en_US
dc.identifier14871670en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/61470
dc.description.abstractLocal surface ooeffioients of heat t-ansfer, overall pressure drop data and mean friction factor are presented for heat flamms up to 3.52106 BtuAr ft2 for water flowing in a nickel tabe isder the following conditions: mass rates of flow up to 5.6x 106 lb.m/hr ft2 (or inlet velocities up to 30 ft/sec), absolute pressures up to 2000 pula, and liquid suboooling between 50 F and 250 T. The test section dmnsins were 0.160 inoh I.D. and 9.4 inches long.en_US
dc.description.sponsorshipOffice of Naval Researchen_US
dc.format.extent[55] leaves in various pagings (some unnumbered)en_US
dc.publisherCambridge, Mass. : M.I.T. Division of Industrial Cooperation, 1951en_US
dc.relation.ispartofseriesTechnical report (Massachusetts Institute of Technology, Heat Transfer Laboratory) ; no. 3.en_US
dc.subjectHeat -- Transmission.en_US
dc.subjectPressure.en_US
dc.titleHeat transfer and pressure drop data for high heat flux densities to water at high subcritical pressuresen_US
dc.typeTechnical Reporten_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record