Show simple item record

dc.contributor.authorHe, David Da
dc.contributor.authorWinokur, Eric S.
dc.contributor.authorSodini, Charles G.
dc.date.accessioned2016-04-20T16:00:24Z
dc.date.available2016-04-20T16:00:24Z
dc.date.issued2015-10
dc.date.submitted2015-06
dc.identifier.issn0018-9294
dc.identifier.issn1558-2531
dc.identifier.urihttp://hdl.handle.net/1721.1/102274
dc.description.abstractThis paper presents a wearable vital signs monitor at the ear. The monitor measures the electrocardiogram (ECG), ballistocardiogram (BCG), and photoplethysmogram (PPG) to obtain pre-ejection period (PEP), stroke volume (SV), cardiac output (CO), and pulse transit time (PTT). The ear is demonstrated as a natural anchoring point for the integrated sensing of physiological signals. All three signals measured can be used to obtain heart rate (HR). Combining the ECG and BCG allows for the estimation of the PEP, while combining the BCG and PPG allows for the measurement of PTT. Additionally, the J-wave amplitude of the BCG is correlated with the SV and, when combined with HR, yields CO. Results from a clinical human study on 13 subjects demonstrate this proof-of-concept device.en_US
dc.description.sponsorshipMIT Medical Electronic Device Realization Centeren_US
dc.language.isoen_US
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1109/TBME.2015.2459061en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceProf. Sodini via Phoebe Ayersen_US
dc.titleAn Ear-Worn Vital Signs Monitoren_US
dc.typeArticleen_US
dc.identifier.citationHe, David Da, Eric S. Winokur, and Charles G. Sodini. “An Ear-Worn Vital Signs Monitor.” IEEE Trans. Biomed. Eng. 62, no. 11 (November 2015): 2547–2552.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.approverSodini, Charles G.en_US
dc.contributor.mitauthorHe, David Daen_US
dc.contributor.mitauthorWinokur, Eric S.en_US
dc.contributor.mitauthorSodini, Charles G.en_US
dc.relation.journalIEEE Transactions on Biomedical Engineeringen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsHe, David Da; Winokur, Eric S.; Sodini, Charles G.en_US
dc.identifier.orcidhttps://orcid.org/0000-0002-0413-8774
mit.licenseOPEN_ACCESS_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record